:00Thu 24 Sep

Put reels in

How a put-in works

Scan the reel, then push it into any empty bay. Nothing is lit: the sensor says where it went, and Janus records it there.

Scanner ready
  1. Scanned, done14:32
  2. Recognised, doneFrom label
  3. Any free bay, done14:32 · green
  4. Sensor didn't see it, needs review, sensor-confirmedNot confirmed · 8 s
  5. Stored, not yet

Step 4 of 5 · Sensor didn't see it · Not confirmed · 8 s · needs review

What the steps mean

A square step is recorded by Janus. A round step is confirmed by the rack’s sensor at the bay.

Not confirmed

The sensor didn't see the reel.

Safe: nothing was recorded. Leave R-2026-0042 in T3-L14.

  1. Then: T3-L14 blinks green again and the sensor watches for 8 s.

  2. Then: the put-in stays open at any station, first in Not finished. The bay keeps blinking green.

  3. Then: a supervisor checks the bay and decides. Bence Tóth is on shift.

SR-01 · Reel rack A

SMT Line 2 · position 1 · 42 empty bays

Online
Tier 3 · bays 9–20front view

L14 · lit

Bay light
Green blinking · put a reel in here. Green · blinking — put the reel in here
Sensor at L14
Empty · not seen in 8 s
Fits
7″ reel · 8 mm tape · 1 bay
Tower lights
Yellow tower · attention on this rack. Left yellow · Off · nothing to do here. Right off

Not finished

1 put-in not finished
  • R-2026-0109 · PN-SMAJ24A
    2 500 pcs from label · The sensor did not see it at SR-01-T4-L31 · covers WO-260714-09's 480 pcs short
    Waiting for sensor
    You12 min ago
3 more in the Review queue
  • R-2026-0118 · PN-0402-100N
    4 000 pcs · default quantity · Started at Station SMT-1, not finished
    Needs review
    Gábor NagyOperator · 1 h 4 min ago
  • R-2026-0121 · PN-QFN32-MCU7
    600 pcs from MES · Sent by MES, waiting for review
    Not put in yet
    MES adapterConnected system · 2 h ago
  • R-2025-0913 · PN-0603-10K
    Quantity unknown · no scan or sensor has seen this reel
    Record, no reel
    Old record · before Janus

Alerts

Faults and blocked work stay here until fixed. Notices can be cleared.

SR-02 is limited

Bence Tóth is on itsince 09:41 · 4 h 51 min14:30 installation map v4 drafted by Dávid Horváth under permit · waiting to be applied

Tier 3, bays 1–16 are Unknown. Blocks 2 take-outs for WO-260714-09 and hides 310 pcs of PN-QFN32-MCU7. The rest of SR-02 works.

Handled by the site administrator.Stays until fixed

Label not recognised

A Würth Elektronik label matched no code rule.

Eszter Szabó is told. Put the reel aside.

Put-in not finished

Reel R-2026-0109 is waiting for the sensor at SR-01-T4-L31: finish putting it in, or cancel.

Counter ReelSave is failing

Owner: line counter vendorsince 13:48

12 messages waiting. SMT Line 2 counters don't know about reels taken out since 13:48.

Handled by the site administrator.

Snapshot taken · 14:30

Verified · off-host copy 14:30. Snapshots every 15 min while Janus is busy.

Choose working rack

Scans and bay lights on this station use the working rack. Opening another rack never switches it.

Racks

Help

What the words mean

Language

Applies to this station only. Records keep the words they were written in.

Enter quantity

The quantity printed on R-2026-0042, or your count. It replaces Unknown as its first quantity: no approval, no variance.

Whole pcs.

Discard this scan?

R-2026-0042 will not be recorded. Scan it again to put it in.

Record, no reel · R-2025-0913

No scan or sensor has seen this reel. Removing the record is a supervisor's decision: send what you found to the Review queue.

  1. A supervisor decides in the Review queue whether to remove the record.

Where you looked. Recorded with your name.

Write at least 4 characters.

Prototype

Put in

Preview stateNot confirmed

Simulate

View as

This page

Purpose
Put reels in by evidence: scan, the bay lights, the sensor confirms.
Release
R1
First viewport
1 primary · 1 notice · 3 blocks