:00Thu 24 Sep
Floor
About the Floor
Yours now is the work that waits for you, in the order it is needed. Ready lists collections waiting in your rack's Ready list; they light when the station there pulls them: Next, a list scan or Start.
As of 14:29 · 3 yours · 5 of 12 in Review at this line
Yours now
- Readyat SR-01 · lights on pullContinue WO-260714-073 reels for SMT Line 2 · due 11:30
- Not finishedWaiting for its sensor at T4-L31Finish putting in R-2026-01092 500 pcs of PN-SMAJ24A · waiting for its sensor at SR-01-T4-L31
- Due backsince 13:48Bring back R-2026-0057 from feeder 141 800 pcs expected of PN-0603-10K · due back since 13:48. Count what is left when it comes back.
Ready at SR-01
- WO-260714-09 → SMT Line 1T1-L20
Your rack
The rack drawing
- Occupied
- Reserved
- Lit
- Unknown · sensor not reporting
- Presumed · not re-confirmed
- Taken, awaiting the rack
- Empty
Others are on it
Show who
- Bence Tóthsince 14:03SR-02 tier 3 stopped reporting · Bays 1–16 Unknown since 09:41: never lit, never read as empty. 1 take-out waiting for the settled read. Latest: 14:18 spare board fitted, answers as board 10, not in wiring yet.
- Bence TóthShift B supervisorWO-260714-09 is 120 pcs short of PN-SMAJ24A · Line 3 closed short 120 pcs at allocation. Accept the shortage or close the order short.
- Bence Tóthsince 14:03COUNT-260714-A · SR-01 tier 5 · 1 difference to post · 1 of 2 differences closed · L30 still to post.
- No ownerwaits for an ownerMissing · R-2026-0088 · booked by Janus · Booked at the Missing delay at 13:22: SR-01-T5-L22 read Clear since 12:52 and no task held the reel. Found it, or decide: taken to line, used up, scrap.
- No ownerwaits for an ownerMissing · R-2026-0175 · booked by Janus · Booked at the Missing delay at 14:32: SR-01-T2-L10 read Clear since 14:21 and no task held the reel. Found it, or decide: taken to line, used up, scrap.
Recent
8 since 09:41
- 14:32Reel stored · R-2026-0042 at SR-01-T3-L14Márta Kovács · 5 000 pcs · sensor confirmed
- 14:31Reel stored · R-2026-0164 at SR-01-T4-L12Márta Kovács · reserved for WO-260714-07 line 4
- 14:20Put-in started · R-2026-0109 at SR-01-T4-L31Márta Kovács · waiting for the sensor
- 13:48Reel taken out · R-2026-0057 → SMT Line 2 · feeder 14Gábor Nagy · 1 800 pcs due back
- 13:05Count counted · 2 differences to post · COUNT-260714-AGábor Nagy · SR-01 tier 5 · 30 of 32 bays confirmed
- 12:52Left its bay without a take-out · SR-01-T5-L22R-2026-0088 · sensor at SR-01-T5-L22
- 11:02Take-out request rejected · R-2026-0103MES adapter · reel reserved by another order
- 09:41Sensors stopped · SR-02 tier 3Sensor reader · board 5 did not answer · bays 1–16