:00Thu 24 Sep

SR-01 · Reel rack A

Online SMT hall › SMT Line 2 · position 1

Technical details
Shape
5 tiers × 32 bays
Controller
CTRL-A01
Address
192.168.0.21
Floor label
POS-L2-01 · Station SMT-2 works on this rack
Working rack on this station

Wiring map

CTRL-A01HF-XGate2-P4192.168.0.21
Firmware
V2.01-2503 · reported 06:02
Built
5 tiers × 32 · 10 bay boards + tower board 11
Towers
Left · right · on board 11
Bus 1
10 of 10 bay boards answer
  • OK
  • Occupied bay

No differences

160 of 160 sensors answer where expected

Left tower on output 1, right tower on output 2.

Tiers, boards and towers

SR-01 boards per tier and tower
TierSensor boardsLight boardsBaysStateLast checked
T5Bus 1 · 9, 10Bus 1 · 9, 1032OKTue 9 Sep · seen by a person
T4Bus 1 · 7, 8Bus 1 · 7, 832OKTue 9 Sep · seen by a person
T3Bus 1 · 5, 6Bus 1 · 5, 632OKTue 9 Sep · seen by a person
T2Bus 1 · 3, 4Bus 1 · 3, 432OKTue 9 Sep · seen by a person
T1Bus 1 · 1, 2Bus 1 · 1, 232OKTue 9 Sep · seen by a person
Left tower—Bus 1 · 11 out 1—OKTue 9 Sep · seen by a person
Right tower—Bus 1 · 11 out 2—OKTue 9 Sep · seen by a person
  1. Tue 9 Sep
    Version 1 turned on · rack added to service
    Dávid Horváth · Rack setup

Matches Wiring version 1 is in use and matches the controller
Last compared 14:31

Alerts

Faults and blocked work stay here until fixed. Notices can be cleared.

SR-02 is limited

Bence Tóth is on itsince 09:41 · 4 h 51 min14:30 installation map v4 drafted by Dávid Horváth under permit · waiting to be applied

Tier 3, bays 1–16 are Unknown. Blocks 2 take-outs for WO-260714-09 and hides 310 pcs of PN-QFN32-MCU7. The rest of SR-02 works.

Troubleshoot SR-02Stays until fixed

Label not recognised

A Würth Elektronik label matched no code rule.

Put-in not finished

Reel R-2026-0109 is waiting for the sensor at SR-01-T4-L31: finish putting it in, or cancel.

Counter ReelSave is failing

Owner: line counter vendorsince 13:48

12 messages waiting. SMT Line 2 counters don't know about reels taken out since 13:48.

Snapshot taken · 14:30

Verified · off-host copy 14:30. Snapshots every 15 min while Janus is busy.

Choose working rack

Scans and bay lights on this station use the working rack. Opening another rack never switches it.

Racks

Help

What the words mean

Language

Applies to this station only. Records keep the words they were written in.

Prototype

Wiring · SR-01

Preview stateSite administrator

View as

This page

Purpose
Boards and channels per tier.
Release
R1
First viewport
1 primary · 1 notice · 3 blocks