:00Thu 24 Sep

Equipment

About Equipment

Racks and where they stand, the stations, handhelds, terminals and phones that work on them, and who holds each device now.

3 reel racks · 1 needs attention · 9 devices

Needs attention

  • T4T3T2T1

    SMT hall › SMT Line 2 · position 2 · no station

    Limitedtier 3 · bays 1–16 unknown · 1 take-out awaiting SR-02

    Dávid Horváth · until 18:00

    86 of 128 occupied16 unknown

    Sensors
    112 of 128 reportingTier 3 · 1–16 · nothing since 09:41
    Tower lights
    Left yellow · sensor data out of date · Right off
    Troubleshoot
    Controller and wiring
    Wiring
    Version 4 drafted under the permit · sent to Eszter Szabó 14:30 · not opened yet
    Controller
    CTRL-B01 · 192.168.0.22 · switch port P2
    Firmware
    V2.01-2503 · reported 06:02
    Response time
    26 ms · board 5 no answer

Working normally

  • T5T4T3T2T1

    SMT hall › SMT Line 2 · position 1 · Station SMT-2 works here

    Onlineyour working rack1 difference on tier 5 · in a count

    118 of 160 occupied42 empty

    Details
    Sensors
    160 of 160 reporting · last full read 0.4 s ago
    Tower lights
    Left off · Right green, blinking · put-in at T4-L31
    Controller
    CTRL-A01 · 192.168.0.21 · switch port P1
    Firmware
    V2.01-2503 · reported 06:02
    Response time
    24 ms
  • T3T2T1

    SMT hall › SMT Line 1 · position 1 · Station SMT-1 works here

    Online

    31 of 48 occupied17 empty

    Details
    Sensors
    48 of 48 reporting · last full read 0.5 s ago
    Shape
    Tier 2 double height · 13″ reels
    Tower lights
    Left off · Right off · red, yellow and green lamps only
    Controller
    CTRL-C01 · 192.168.0.23 · switch port P3
    Firmware
    R3-1.4.2 · expected, the controller doesn’t report it
    Response time
    31 ms
  • Occupied
  • Reserved
  • Empty
  • Difference
  • Unknown
  • Double-height tier

Being set up

SR-04 · Line-side rack D

In service · in handover
T4T3T2T1T4T3T2T1
Place
SMT hall › SMT Line 2 · position 3 · POS-L2-03
Rack label
RACK-SR-04 · printed at Add to service
Shape
2 sides · 4 tiers × 16 bays · tier 4 double height · 128 bays
Tower lights
Side A tower · Side B tower · both off
Controller
HF-XGate2-P4 · 0410-202506-001-0311
Address
192.168.0.25 · from the pool
Set up by
Dávid Horváth

In service since 14:32 · checks passed 14:31 · self-test optional. Dávid Horváth keeps self-test, identify and a layout draft until you accept.

Then: his rights on SR-04 end and the setup record reads “Built by Dávid Horváth · accepted by Eszter Szabó”.

Open SR-04

Areas and lines

About areas and lines

Every rack stands at a floor position on one of these lines or stores. A rack’s line is chosen in its Settings › Place; standing somewhere else is a Move. Floor labels keep their printed codes when a line is renamed.

Areas and lines
Line or storeKindFloor positionsRacks here
SMT hall2 lines
SMT Line 1Production line 3 · 1 free SR-03 at position 1 · SR-05 at position 2 · planned
SMT Line 2Production line 4 · 1 free SR-01 at position 1 · SR-02 at position 2 · SR-04 at position 3 · being set up
Stores3 stores
Store AStore 4 · 4 free No rack
Stencil roomStore 1 · all taken ST-01 at position 1
Goods-in dockStore None No rack

Stations and devices

When a device is Late

A device is Online if Janus heard it in the last 30 s, Late up to 2 min, then Offline.

PDA-03 is Late since 14:30:57 · 21 % battery · a count is open on it

László Varga is counting COUNT-260714-B at SR-03 tier 1 · 10 of 16 bays. Wi-Fi 40 % at SMT Line 1. His counted bays are kept on the handheld until it reaches Janus.

Open the count
Stations and devices
DeviceHolder or rackLast seenBatterySignalStateActions
Stations · kiosk and desk scanner, bound to a rack
Station SMT-215.6″ kiosk · desk scanner · STN-SMT2Márta Kovács · since 14:00Home rack SR-01 · working rack SR-01SMT Line 2 · at SR-014 s agoMainsWiredOnline
Intake SR-0115.6″ kiosk · desk scanner · STN-IN01 · rack intakeNobody signed in · the station actsHome rack SR-01 · working rack SR-01SMT Line 2 · at the SR-01 rack end3 s agoMainsWiredOnline
Station SMT-115.6″ kiosk · desk scanner · STN-SMT1Oleh Bondar · since 14:02Home rack SR-03 · working rack SR-03SMT Line 1 · at SR-036 s agoMainsWiredOnline
Handhelds · signed in by badge, follow their person
PDA-03Handheld · Zebra-class, 4.3″László Varga · since 14:05Counting COUNT-260714-B · working rack SR-03SMT Line 1 · at SR-0314:30:5721 %40 %Latesince 14:30:57
PDA-04Handheld · Zebra-class, 5″Márta Kovács · for work away from the stationIn its cradle at Station SMT-2 nowSMT Line 2 · at SR-018 s ago78 %92 %Onlinecharging
Line terminals · feeder side, no rack
LT-SMT2Line terminal · SMT Line 2 feeder sideNo rackAnyone on Shift A or B signs in by badge · nobody nowSMT Line 2 · feeder side12 s agoMainsWiredOnline
LT-SMT1Line terminal · SMT Line 1 feeder sideNo rackAnyone on Shift A or B signs in by badge · nobody nowSMT Line 1 · feeder side4 s agoMainsWiredOnline
Printers
Label printer SMT-2Bay, rack and floor labelsAt Station SMT-2Default for rack and bay labelsSMT Line 220 s agoMainsWiredReadylabels 62 %
Personal phones · allowed per person in People
Bence Tóth’s phoneCamera scan · paired Tue 16 SepBence Tóth · supervisorWorking rack SR-01 · a rack label scanned switches itSMT Line 2 · scanned at SR-0114:31Not reportedWi-FiSigned inOpen person
Dávid Horváth’s phoneCamera scan · paired 14:19 today by QRDávid Horváth · installerService visit until Sun 28 Sep 18:00 · then unpairedSMT Line 2 · at SR-0214:30Not reportedWi-FiSigned inOpen person

Parked racks

2 parked · Later · not in R1
Later · not in R1Neo 0032 §24; PRD §1.4

Stencil racks: stencils stored by slot, their tower, and taking a stencil out to a printer

Not in R1
Neo keeps the model shape for stencils but defers their qualification and journeys until after R1: release 1 stores reels only
R1 instead
Reel racks only. Stencils stay where the site keeps them today, outside Janus Open it

SR-05 · Stencil rack E · ST-01 · Stencil tower

Alerts

Faults and blocked work stay here until fixed. Notices can be cleared.

SR-02 is limited

Bence Tóth is on itsince 09:41 · 4 h 51 min14:30 installation map v4 drafted by Dávid Horváth under permit · waiting to be applied

Tier 3, bays 1–16 are Unknown. Blocks 2 take-outs for WO-260714-09 and hides 310 pcs of PN-QFN32-MCU7. The rest of SR-02 works.

Troubleshoot SR-02Stays until fixed

Label not recognised

A Würth Elektronik label matched no code rule.

Put-in not finished

Reel R-2026-0109 is waiting for the sensor at SR-01-T4-L31: finish putting it in, or cancel.

Counter ReelSave is failing

Owner: line counter vendorsince 13:48

12 messages waiting. SMT Line 2 counters don't know about reels taken out since 13:48.

Snapshot taken · 14:30

Verified · off-host copy 14:30. Snapshots every 15 min while Janus is busy.

Choose working rack

Scans and bay lights on this station use the working rack. Opening another rack never switches it.

Racks

Help

What the words mean

Language

Applies to this station only. Records keep the words they were written in.

Add a device

Personal phones are not added here: they are a permission of the person, in People.

Kind

One name, used on the device, in People and in Activity.

Janus shows an enrolment QR, valid for 10 min. Scan it with the device’s Janus app, or give IT the managed config for your device management.

Then: name it.

Station SMT-2

15.6″ kiosk · desk scanner · at SR-01

Now
Márta Kovács · since 14:00 · working rack SR-01
Place
SMT Line 2 · at SR-01 (position 1)
Set by
Eszter Szabó · Tue 9 Sep

Its default working rack. An operator’s switch lasts for the session and returns here at sign-out.

Who may sign in

Unlocks with a badge scan.

Check-in key and removal

Replace the key if the device was lost or reset. Removing it signs out whoever holds it; past scans keep its name in Activity.

Replace the check-in key?

The current key stops working now. The device shows Late, then Offline, until it scans a new enrolment QR.

Recorded with your name in Activity.

Write at least 4 characters.

Remove Station SMT-2?

Its key stops working, whoever holds it is signed out, and it leaves this list. Past scans made on it keep its name in Activity. This can't be undone.

Station SMT-1

15.6″ kiosk · desk scanner · at SR-03

Now
Oleh Bondar · since 14:02 · working rack SR-03
Place
SMT Line 1 · at SR-03 (position 1)
Set by
Eszter Szabó · Thu 11 Sep

Its default working rack. An operator’s switch lasts for the session and returns here at sign-out.

Who may sign in

Unlocks with a badge scan.

Check-in key and removal

Replace the key if the device was lost or reset. Removing it signs out whoever holds it; past scans keep its name in Activity.

Replace the check-in key?

The current key stops working now. The device shows Late, then Offline, until it scans a new enrolment QR.

Recorded with your name in Activity.

Write at least 4 characters.

Remove Station SMT-1?

Its key stops working, whoever holds it is signed out, and it leaves this list. Past scans made on it keep its name in Activity. This can't be undone.

PDA-03

Handheld · Zebra-class, 4.3″

Now
László Varga · counting COUNT-260714-B · working rack SR-03
Last seen
14:30:57 at SR-03 · Wi-Fi 40 % · battery 21 %
Signs in by
Badge scan · passcode as fallback
Working rack
Follows its person · a rack label scan switches it
Low battery
Warns below 20 % during a task

Unlocks with a badge scan.

Check-in key and removal

Replace the key if the device was lost or reset. Removing it signs out whoever holds it; past scans keep its name in Activity.

Replace the check-in key?

The current key stops working now. The device shows Late, then Offline, until it scans a new enrolment QR.

Recorded with your name in Activity.

Write at least 4 characters.

Remove PDA-03?

Its key stops working, whoever holds it is signed out, and it leaves this list. Past scans made on it keep its name in Activity. This can't be undone.

PDA-04

Handheld · Zebra-class, 5″

Now
Márta Kovács · in its cradle at Station SMT-2
Last seen
8 s ago · Wi-Fi 92 % · battery 78 %, charging
Signs in by
Badge scan · passcode as fallback
Working rack
Follows its person · a rack label scan switches it
Low battery
Warns below 20 % during a task

Unlocks with a badge scan.

Check-in key and removal

Replace the key if the device was lost or reset. Removing it signs out whoever holds it; past scans keep its name in Activity.

Replace the check-in key?

The current key stops working now. The device shows Late, then Offline, until it scans a new enrolment QR.

Recorded with your name in Activity.

Write at least 4 characters.

Remove PDA-04?

Its key stops working, whoever holds it is signed out, and it leaves this list. Past scans made on it keep its name in Activity. This can't be undone.

LT-SMT2

Line terminal · SMT Line 2 feeder side

Now
Nobody signed in · no rack
Last seen
12 s ago · wired

Unlocks with a badge scan.

Check-in key and removal

Replace the key if the device was lost or reset. Removing it signs out whoever holds it; past scans keep its name in Activity.

Replace the check-in key?

The current key stops working now. The device shows Late, then Offline, until it scans a new enrolment QR.

Recorded with your name in Activity.

Write at least 4 characters.

Remove LT-SMT2?

Its key stops working, whoever holds it is signed out, and it leaves this list. Past scans made on it keep its name in Activity. This can't be undone.

LT-SMT1

Line terminal · SMT Line 1 feeder side

Now
Nobody signed in · no rack
Last seen
4 s ago · wired

Unlocks with a badge scan.

Check-in key and removal

Replace the key if the device was lost or reset. Removing it signs out whoever holds it; past scans keep its name in Activity.

Replace the check-in key?

The current key stops working now. The device shows Late, then Offline, until it scans a new enrolment QR.

Recorded with your name in Activity.

Write at least 4 characters.

Remove LT-SMT1?

Its key stops working, whoever holds it is signed out, and it leaves this list. Past scans made on it keep its name in Activity. This can't be undone.

Areas and lines

Danutek · Line 2 site. Racks choose their line in Settings › Place.

SMT hall · 2 lines

SMT Line 1

3 floor positions · SR-03, SR-05 stand here, so it stays.

SMT Line 2

4 floor positions · SR-01, SR-02, SR-04 stand here, so it stays.

Stores · 3 stores

Store A
Stencil room

1 floor positions · ST-01 stands here, so it stays.

Goods-in dock
Add a line or store

Leave the name empty to add nothing. Its floor positions get labels to print.

0 to 8

A hall, a store room or a building. Add its lines after saving.

Then: every rack’s place reads the new names on every page. Floor labels keep their printed codes; nothing moves on the floor.

Export hierarchy

Danutek · Line 2 site · as of 14:32. A preview: nothing is sent from here.

Hierarchy
AreaLine or storeExported asRacks (StorageUnit)
SMT hallSMT Line 1ProductionLineSR-03 at POS-L1-01 · SR-05 at POS-L1-02
SMT hallSMT Line 2ProductionLineSR-01 at POS-L2-01 · SR-02 at POS-L2-02 · SR-04 at POS-L2-03
StoresStore AStorageZoneNone
StoresStencil roomStorageZoneST-01 at POS-ST-01
StoresGoods-in dockStorageZoneNone

As ISA-95 equipment hierarchy: site = Site · area = Area · line = ProductionLine · store = StorageZone · rack = StorageUnit, with its floor label and place as properties · bay = the storage location of a reel (a material sublot).

<?xml version="1.0" encoding="UTF-8"?>
<ShowEquipment xmlns="http://www.mesa.org/xml/B2MML" releaseID="7.0">
  <ApplicationArea><Sender><LogicalID>Janus · Danutek · Line 2 site</LogicalID></Sender><CreationDateTime>2026-09-24T14:32:00+02:00</CreationDateTime></ApplicationArea>
  <DataArea>
    <Show/>
    <Equipment>
      <ID>DN02</ID>
      <Description>Line 2 site</Description>
      <EquipmentLevel>Site</EquipmentLevel>
      <Equipment>
        <ID>DN02.SMT</ID>
        <Description>SMT hall</Description>
        <EquipmentLevel>Area</EquipmentLevel>
        <Equipment>
          <ID>DN02.L1</ID>
          <Description>SMT Line 1</Description>
          <EquipmentLevel>ProductionLine</EquipmentLevel>
          <Equipment>
            <ID>SR-03</ID>
            <Description>Line-side rack C</Description>
            <EquipmentLevel>StorageUnit</EquipmentLevel>
            <EquipmentProperty><ID>FloorLabel</ID><Value><ValueString>POS-L1-01</ValueString></Value></EquipmentProperty>
            <EquipmentProperty><ID>Place</ID><Value><ValueString>SMT Line 1 · position 1</ValueString></Value></EquipmentProperty>
          </Equipment>
          <Equipment>
            <ID>SR-05</ID>
            <Description>Stencil rack E</Description>
            <EquipmentLevel>StorageUnit</EquipmentLevel>
            <EquipmentProperty><ID>FloorLabel</ID><Value><ValueString>POS-L1-02</ValueString></Value></EquipmentProperty>
            <EquipmentProperty><ID>Place</ID><Value><ValueString>SMT Line 1 · position 2</ValueString></Value></EquipmentProperty>
          </Equipment>
        </Equipment>
        <Equipment>
          <ID>DN02.L2</ID>
          <Description>SMT Line 2</Description>
          <EquipmentLevel>ProductionLine</EquipmentLevel>
          <Equipment>
            <ID>SR-01</ID>
            <Description>Reel rack A</Description>
            <EquipmentLevel>StorageUnit</EquipmentLevel>
            <EquipmentProperty><ID>FloorLabel</ID><Value><ValueString>POS-L2-01</ValueString></Value></EquipmentProperty>
            <EquipmentProperty><ID>Place</ID><Value><ValueString>SMT Line 2 · position 1</ValueString></Value></EquipmentProperty>
          </Equipment>
          <Equipment>
            <ID>SR-02</ID>
            <Description>High-capacity rack B</Description>
            <EquipmentLevel>StorageUnit</EquipmentLevel>
            <EquipmentProperty><ID>FloorLabel</ID><Value><ValueString>POS-L2-02</ValueString></Value></EquipmentProperty>
            <EquipmentProperty><ID>Place</ID><Value><ValueString>SMT Line 2 · position 2</ValueString></Value></EquipmentProperty>
          </Equipment>
          <Equipment>
            <ID>SR-04</ID>
            <Description>Line-side rack D</Description>
            <EquipmentLevel>StorageUnit</EquipmentLevel>
            <EquipmentProperty><ID>FloorLabel</ID><Value><ValueString>POS-L2-03</ValueString></Value></EquipmentProperty>
            <EquipmentProperty><ID>Place</ID><Value><ValueString>SMT Line 2 · position 3</ValueString></Value></EquipmentProperty>
          </Equipment>
        </Equipment>
      </Equipment>
      <Equipment>
        <ID>DN02.STORES</ID>
        <Description>Stores</Description>
        <EquipmentLevel>Area</EquipmentLevel>
        <Equipment>
          <ID>DN02.SA</ID>
          <Description>Store A</Description>
          <EquipmentLevel>StorageZone</EquipmentLevel>
        </Equipment>
        <Equipment>
          <ID>DN02.ST</ID>
          <Description>Stencil room</Description>
          <EquipmentLevel>StorageZone</EquipmentLevel>
          <Equipment>
            <ID>ST-01</ID>
            <Description>Stencil tower</Description>
            <EquipmentLevel>StorageUnit</EquipmentLevel>
            <EquipmentProperty><ID>FloorLabel</ID><Value><ValueString>POS-ST-01</ValueString></Value></EquipmentProperty>
            <EquipmentProperty><ID>Place</ID><Value><ValueString>Stencil room · position 1</ValueString></Value></EquipmentProperty>
          </Equipment>
        </Equipment>
        <Equipment>
          <ID>DN02.GI</ID>
          <Description>Goods-in dock</Description>
          <EquipmentLevel>StorageZone</EquipmentLevel>
        </Equipment>
      </Equipment>
    </Equipment>
  </DataArea>
</ShowEquipment>
{
  "enterprise": "Danutek",
  "site": {
    "id": "DN02",
    "name": "Line 2 site",
    "level": "Site"
  },
  "asOf": "2026-09-24T14:32:00+02:00",
  "areas": [
    {
      "id": "DN02.SMT",
      "name": "SMT hall",
      "level": "Area",
      "lines": [
        {
          "id": "DN02.L1",
          "name": "SMT Line 1",
          "level": "ProductionLine",
          "racks": [
            {
              "id": "SR-03",
              "name": "Line-side rack C",
              "level": "StorageUnit",
              "floorLabel": "POS-L1-01",
              "place": "SMT Line 1 · position 1"
            },
            {
              "id": "SR-05",
              "name": "Stencil rack E",
              "level": "StorageUnit",
              "floorLabel": "POS-L1-02",
              "place": "SMT Line 1 · position 2"
            }
          ]
        },
        {
          "id": "DN02.L2",
          "name": "SMT Line 2",
          "level": "ProductionLine",
          "racks": [
            {
              "id": "SR-01",
              "name": "Reel rack A",
              "level": "StorageUnit",
              "floorLabel": "POS-L2-01",
              "place": "SMT Line 2 · position 1"
            },
            {
              "id": "SR-02",
              "name": "High-capacity rack B",
              "level": "StorageUnit",
              "floorLabel": "POS-L2-02",
              "place": "SMT Line 2 · position 2"
            },
            {
              "id": "SR-04",
              "name": "Line-side rack D",
              "level": "StorageUnit",
              "floorLabel": "POS-L2-03",
              "place": "SMT Line 2 · position 3"
            }
          ]
        }
      ]
    },
    {
      "id": "DN02.STORES",
      "name": "Stores",
      "level": "Area",
      "lines": [
        {
          "id": "DN02.SA",
          "name": "Store A",
          "level": "StorageZone",
          "racks": []
        },
        {
          "id": "DN02.ST",
          "name": "Stencil room",
          "level": "StorageZone",
          "racks": [
            {
              "id": "ST-01",
              "name": "Stencil tower",
              "level": "StorageUnit",
              "floorLabel": "POS-ST-01",
              "place": "Stencil room · position 1"
            }
          ]
        },
        {
          "id": "DN02.GI",
          "name": "Goods-in dock",
          "level": "StorageZone",
          "racks": []
        }
      ]
    }
  ]
}

B2MML is the XML form of ISA-95 (IEC 62264). Integrations offers it as a preset for an MES that asks for it.

Download XMLDownload JSON

Prototype

Racks and devices · Equipment

Preview stateSR-04 in handover · after Add

View as

This page

Purpose
Racks and devices.
Release
R1
First viewport
1 primary · 1 notice · 3 blocks