Equipment
About Equipment
Racks and where they stand, the stations, handhelds, terminals and phones that work on them, and who holds each device now.
3 reel racks · 1 needs attention · 9 devices
Needs attention
- T4T3T2T1
SMT hall › SMT Line 2 · position 2 · no station
Limitedtier 3 · bays 1–16 unknown · 1 take-out awaiting SR-02
Dávid Horváth · until 18:00
86 of 128 occupied16 unknown
Controller and wiring
- Wiring
- Version 4 drafted under the permit · sent to Eszter Szabó 14:30 · not opened yet
- Controller
- CTRL-B01 · 192.168.0.22 · switch port P2
- Firmware
- V2.01-2503 · reported 06:02
- Response time
- 26 ms · board 5 no answer
Working normally
- T5T4T3T2T1
SMT hall › SMT Line 2 · position 1 · Station SMT-2 works here
Onlineyour working rack1 difference on tier 5 · in a count
118 of 160 occupied42 empty
Details
- Sensors
- 160 of 160 reporting · last full read 0.4 s ago
- Tower lights
- Left off · Right green, blinking · put-in at T4-L31
- Controller
- CTRL-A01 · 192.168.0.21 · switch port P1
- Firmware
- V2.01-2503 · reported 06:02
- Response time
- 24 ms
- T3T2T1
SMT hall › SMT Line 1 · position 1 → position 3
Being movedby Dávid Horváth · offline expected until 14:50
12 min of 30 · no put-in or take-out · 2 reserved reels wait
31 of 48 occupied17 empty
Details
- Sensors
- 48 of 48 reporting · last full read 0.5 s ago
- Shape
- Tier 2 double height · 13″ reels
- Tower lights
- Both yellow, slow blink · SR-03’s own move rule (no blue lamp)
- Controller
- CTRL-C01 · 192.168.0.23 · switch port P3
- Firmware
- R3-1.4.2 · expected, the controller doesn’t report it
- Response time
- 31 ms
- Occupied
- Reserved
- Empty
- Difference
- Unknown
- Double-height tier
Being set up
SR-04 · Line-side rack D
Being set up · at Address- Place
- SMT hall › SMT Line 2 · position 3 · POS-L2-03
- Rack label
- RACK-SR-04 · printed at Add to service
- Shape
- 2 sides · 4 tiers × 16 bays · tier 4 double height · 128 bays
- Tower lights
- Side A tower · Side B tower · both off
- Controller
- HF-XGate2-P4 · 0410-202506-001-0311
- Address
- 192.168.0.10 · factory default · the Address step moves it to .25
- Set up by
- Dávid Horváth
Areas and lines
About areas and lines
Every rack stands at a floor position on one of these lines or stores. A rack’s line is chosen in its Settings › Place; standing somewhere else is a Move. Floor labels keep their printed codes when a line is renamed.
| Line or store | Kind | Floor positions | Racks here |
|---|---|---|---|
| SMT hall | |||
| SMT Line 1 | Production line | 3 · 1 free | SR-03 at position 1 · SR-05 at position 2 · planned |
| SMT Line 2 | Production line | 4 · 1 free | SR-01 at position 1 · SR-02 at position 2 · SR-04 at position 3 · being set up |
| Stores | |||
| Store A | Store | 4 · 4 free | No rack |
| Stencil room | Store | 1 · all taken | ST-01 at position 1 |
| Goods-in dock | Store | None | No rack |
Stations and devices
When a device is Late
A device is Online if Janus heard it in the last 30 s, Late up to 2 min, then Offline.
PDA-03 is Late since 14:30:57 · 21 % battery · a count is open on it
László Varga is counting COUNT-260714-B at SR-03 tier 1 · 10 of 16 bays. Wi-Fi 40 % at SMT Line 1. His counted bays are kept on the handheld until it reaches Janus.
| Device | Holder or rack | Last seen | Battery | Signal | State | Actions |
|---|---|---|---|---|---|---|
| Stations · kiosk and desk scanner, bound to a rack | ||||||
| Station SMT-215.6″ kiosk · desk scanner · STN-SMT2 | Márta Kovács · since 14:00Home rack SR-01 · working rack SR-01 | SMT Line 2 · at SR-014 s ago | Mains | Wired | Online | |
| Intake SR-0115.6″ kiosk · desk scanner · STN-IN01 · rack intake | Nobody signed in · the station actsHome rack SR-01 · working rack SR-01 | SMT Line 2 · at the SR-01 rack end3 s ago | Mains | Wired | Online | |
| Station SMT-115.6″ kiosk · desk scanner · STN-SMT1 | Oleh Bondar · since 14:02Home rack SR-03 · working rack SR-03 | SMT Line 1 · at SR-036 s ago | Mains | Wired | Online | |
| Handhelds · signed in by badge, follow their person | ||||||
| PDA-03Handheld · Zebra-class, 4.3″ | László Varga · since 14:05Counting COUNT-260714-B · working rack SR-03 | SMT Line 1 · at SR-0314:30:57 | 21 % | 40 % | Latesince 14:30:57 | |
| PDA-04Handheld · Zebra-class, 5″ | Márta Kovács · for work away from the stationIn its cradle at Station SMT-2 now | SMT Line 2 · at SR-018 s ago | 78 % | 92 % | Onlinecharging | |
| Line terminals · feeder side, no rack | ||||||
| LT-SMT2Line terminal · SMT Line 2 feeder side | No rackAnyone on Shift A or B signs in by badge · nobody now | SMT Line 2 · feeder side12 s ago | Mains | Wired | Online | |
| LT-SMT1Line terminal · SMT Line 1 feeder side | No rackAnyone on Shift A or B signs in by badge · nobody now | SMT Line 1 · feeder side4 s ago | Mains | Wired | Online | |
| Printers | ||||||
| Label printer SMT-2Bay, rack and floor labels | At Station SMT-2Default for rack and bay labels | SMT Line 220 s ago | Mains | Wired | Readylabels 62 % | |
| Personal phones · allowed per person in People | ||||||
| Bence Tóth’s phoneCamera scan · paired Tue 16 Sep | Bence Tóth · supervisorWorking rack SR-01 · a rack label scanned switches it | SMT Line 2 · scanned at SR-0114:31 | Not reported | Wi-Fi | Signed in | Open person |
| Dávid Horváth’s phoneCamera scan · paired 14:19 today by QR | Dávid Horváth · installerService visit until Sun 28 Sep 18:00 · then unpaired | SMT Line 2 · at SR-0214:30 | Not reported | Wi-Fi | Signed in | Open person |
Parked racks
2 parked · Later · not in R1
Stencil racks: stencils stored by slot, their tower, and taking a stencil out to a printer
- Not in R1
- Neo keeps the model shape for stencils but defers their qualification and journeys until after R1: release 1 stores reels only
- R1 instead
- Reel racks only. Stencils stay where the site keeps them today, outside Janus Open it