:00Thu 24 Sep

Counts

How a count works

A count checks identity: at each bay the counter pulls the reel, scans it and pushes it back, and the sensor confirms it back in its bay. The sensor confirms the empty bays without a visit.

Where the record and the count disagree, a supervisor posts the difference with an existing movement. A closed count is final; a recount is a new count.

1 to post · 1 open

  • Counted · differences to post 1

  • SR-01 · tier 5 · 32 bays
    Counted · 1 difference to post32 lines · counted 13:05
    Gábor NagyCounted · you post the differences
    Details
    RecordL22 · R-2026-0088 · 2 150 pcsCountFound empty · an unexpected removal since 12:52
    RecordL30 · emptyCountFound a reel · there since Fri 19 Sep 16:40
  • Open · counting 1

  • SR-03 · tier 1 · 16 bays
    opened 14:06 by Bence Tóth
    László VargaCounting · PDA-03, then Station SMT-1
    Details
    RecordT1-L04 · R-2026-0098CountFound empty · reads Clear
  • Closed 3

  • COUNT-260713-A
    SR-01 · tiers 1–4 · 128 bays
    Closed · no differencesTue 23 Sep 21:40
    Bence TóthClosed · supervisor
  • COUNT-260712-A
    SR-02 · tiers 1–2 · 64 bays
    Closed · 3 differences postedMon 22 Sep 15:12
    Bence TóthClosed · supervisor
  • COUNT-260709-A
    SR-03 · tier 1 · 16 bays
    Closed · no differencesFri 19 Sep 10:02
    Márta KovácsClosed · supervisor

Alerts

Faults and blocked work stay here until fixed. Notices can be cleared.

SR-02 is limited

Bence Tóth is on itsince 09:41 · 4 h 51 min14:30 installation map v4 drafted by Dávid Horváth under permit · waiting to be applied

Tier 3, bays 1–16 are Unknown. Blocks 2 take-outs for WO-260714-09 and hides 310 pcs of PN-QFN32-MCU7. The rest of SR-02 works.

Troubleshoot SR-02Stays until fixed

Label not recognised

A Würth Elektronik label matched no code rule.

Eszter Szabó is told. Put the reel aside.

Put-in not finished

Reel R-2026-0109 is waiting for the sensor at SR-01-T4-L31: finish putting it in, or cancel.

Counter ReelSave is failing

Owner: line counter vendorsince 13:48

12 messages waiting. SMT Line 2 counters don't know about reels taken out since 13:48.

Handled by the site administrator.

Snapshot taken · 14:30

Verified · off-host copy 14:30. Snapshots every 15 min while Janus is busy.

Choose working rack

Scans and bay lights on this station use the working rack. Opening another rack never switches it.

Racks

Help

What the words mean

Language

Applies to this station only. Records keep the words they were written in.

New count

What a new count does

A count checks which reel is in each bay. It opens at once and no one is assigned: any operator at a station or handheld serving the rack picks it.

Production continues; only the bay being checked is held.

  1. RackSR-01 (done)
  2. Sectionstier 5
  3. Opencounted at the rack
Rack
Sections of SR-01
What is counted
21bays to visit
11 confirmed empty by the sensor when it opens · 32 bays

COUNT-260713-A

Closed counts are final. A recount is a new count.

Recorded · No differences

Lines
128 lines · 91 checked · 37 confirmed empty by the sensor
Closed by
Bence Tóth
Closed
Tue 23 Sep 21:40
Posted
—
Open in Activity

COUNT-260712-A

Closed counts are final. A recount is a new count.

Recorded · 3 differences posted

Lines
64 lines · 40 checked · 21 confirmed empty · 3 differences
Closed by
Bence Tóth
Closed
Mon 22 Sep 15:12
Posted
T1-L04 Report missing (by decision) · T2-L18 and T2-L29 found by scan, recorded there
Open in Activity

COUNT-260709-A

Closed counts are final. A recount is a new count.

Recorded · No differences

Lines
16 lines · 11 checked · 5 confirmed empty by the sensor
Closed by
Márta Kovács
Closed
Fri 19 Sep 10:02
Posted
—
Open in Activity

Prototype

Counts

Preview stateCounts

View as

This page

Purpose
Counts: pull, scan, push back; the sensor confirms the empty bays.
Release
R1
First viewport
1 primary · 1 notice · 3 blocks