:00Thu 24 Sep

Dávid Horváth, Danutek technician account

Always on while R1 is trialled. Every action is logged under this named account; it is not a site user.

SR-03 · Line-side rack C

Online SMT hall › SMT Line 1 · position 1

Technical details
Shape
3 tiers × 16 bays · tier 2 double height
Controller
CTRL-C01
Address
192.168.0.23
Floor label
POS-L1-01 · Station SMT-1 works on this rack

No job on SR-03

What you can do without a permit

You can identify the rack, read its sensors and try to reconnect it. Anything else needs a permit from the person who owns it.

Reels Janus doesn’t know

Every bay that reads a reel has a record.

Bays

T3T2T1
  • Occupied
  • Empty
  • Reserved
  • Double height · 13″
Left tower off · Right tower off
Bays as a list
SR-03 bays
BayRecordSensorSize
SR-03-T2-L09R-2026-0140
Reserved · WO-260714-07 · item 7
Reel13″
SR-03-T3-L04R-2026-0158
PN-SMAJ24CA · 600 pcs · approved substitute for WO-260714-09
Reel7″
SR-03-T1-L08R-2026-0034
Reserved · replenishment to SMT Line 2 · feeder 3
Reel7″

Showing a few of 48. Open Inventory to search and export every bay.

Connection path

  1. Janus serverjanus-smt-line2Running
  2. Rack networken5 · approved Mon 18 AugOnline
  3. Controller CTRL-C01192.168.0.23:502Online since 06:02 · 31 ms
  4. RS-485 bus 13 of 3 boards answerOK
  5. Sensors48 of 48 reportingOK

Identify

T3T2T1

Tiers light amber in turn, then the rack flashes twice. 3 s.

Tower lights

  • Left tower Off
    no rule matches
  • Right tower Off
    no rule matches

Tower rules · the first match wins on each tower

Which readings count

When a reading counts

A reading counts only when the board answered, in the current connection, and newer than the last one Janus used. The controller saying “received” is not a reading.

SR-03 readings per board
Part of tierBoardReadingLast good readingCounts
Tier 1 · 1–16board 1OK0.4 s agoYes
Tier 2 · 1–16board 2OK0.7 s agoYes
Tier 3 · 1–16board 3OK0.3 s agoYes

Controller link

Response time
31ms
median of the last 60 reads
Reads per second
12
all 3 bay boards answering
Waiting to send
0
nothing waiting
Last full read
0.4s
complete
Technical details for IT
Model
Rack03 · serial R03-2025-0077
Address
192.168.0.23:502 · switch port P3
Firmware
R3-1.4.2 · expected · the controller doesn’t report it
Boards
3 bay boards + tower board 4 · left tower out 1 · right tower out 2
Profile
janus.light-grid.xgate-tera-input.v1
  1. 12:48
    Reserved · R-2026-0034 at T1-L08
    MES adapter · replenishment to SMT Line 2 · feeder 3
  2. 10:55
    Reserved · R-2026-0140 at T2-L09
    Janus · WO-260714-07 · item 7
  3. 06:02
    Controller online
    Janus · after planned restart

Place

About place

Where the rack stands. It changes only through Move; bays and reels keep their records.

Where
SMT hall › SMT Line 1 · position 1
Floor label
POS-L1-01 · on the floor in front of the rack
Rack labels
RACK-SR-03 · one on each end
Home station
Station SMT-1 · its default working rack · set in Equipment
Switch port
P3 · seen 06:02
Place history · 1at SMT Line 1 · position 1 since Thu 11 Sep
  • SMT Line 1 · position 1
    since Thu 11 Sep · Set up there by Dávid Horváth

Setup

  1. IdentifyThu 11 Sep (done)
  2. NameSR-03 (done)
  3. Where it isSMT Line 1 · position 1 (done)
  4. Address192.168.0.23 (done)
  5. Shape3 × 16 (done)
  6. Check it answersPassed (done)
  7. Add to serviceThu 11 Sep (done)

Added to service by Dávid Horváth on Thu 11 Sep.

Storage and shape

About storage and shape

Bay widths and names change in Layout.

Holds
Reels
Shape
One side · 3 tiers × 16 bays · tier 2 double height
Bays
48 · tier 2 double height for 13″ reels · 1 board per tier
Tower lights
2 · left end and right end, each set on its own
Names
SR-03-T{tier}-L{bay}

Rack behaviour

About rack behaviour

Written to the controller. Sensor timing for all racks is in Site rules.

%

Saved: 80 %

ms

Saved: 1000 ms

Versions · 13in use since Mon 22 Sep
  1. v13Eszter Szabó · Mon 22 Sep 09:10 · 1 changeIn useSee changes
  2. v12Gábor Szabó · Thu 18 Sep 15:40 · 1 changeSee changes
  3. v11Dávid Horváth · Mon 25 Aug · added to serviceSee changes

How often Janus reads each board

About how often janus reads each board

Set by Janus. A board with no answer is read less often.

SR-03 read pace per board
BoardReadsPaceActualWhy
board 1Tier 1Normal410 ms—
board 2Tier 2Normal420 ms—
board 3Tier 3Normal430 ms—

Retire this rack

About retire this rack

Empty it, switch it off, then retire it.

  1. Check2 things block this
  2. Emptying
  3. Switched off
  4. Retired
  • Blocks31 reels must be moved out first
  • Blocks2 reels reserved
  • OKNo count or missing-reel work open

Retired racks keep their history; their bays are closed and can't be reopened. To use the rack again, set it up again.

Not available until the blockers are cleared.

In service

Alerts

Faults and blocked work stay here until fixed. Notices can be cleared.

SR-02 is limited

Bence Tóth is on itsince 09:41 · 4 h 51 min14:30 installation map v4 drafted by Dávid Horváth under permit · waiting to be applied

Tier 3, bays 1–16 are Unknown. Blocks 2 take-outs for WO-260714-09 and hides 310 pcs of PN-QFN32-MCU7. The rest of SR-02 works.

Troubleshoot SR-02Stays until fixed

Label not recognised

A Würth Elektronik label matched no code rule.

Eszter Szabó is told. Put the reel aside.

Put-in not finished

Reel R-2026-0109 is waiting for the sensor at SR-01-T4-L31: finish putting it in, or cancel.

Márta Kovács is on it.

Counter ReelSave is failing

Owner: line counter vendorsince 13:48

12 messages waiting. SMT Line 2 counters don't know about reels taken out since 13:48.

Handled by the site administrator.

Snapshot taken · 14:30

Verified · off-host copy 14:30. Snapshots every 15 min while Janus is busy.

Help

What the words mean

Language

Applies to this station only. Records keep the words they were written in.

SR-03-T3-L01

Tier 3 · bay 1 · 7″

Record

R-2026-0819
PN-SOT23-2N7002 · N-MOSFET 60 V
3 000pcs

Sensor

Reel

0.4 s ago

Record and sensor match.
Open R-2026-0819
Holds
Reels up to 7″
Bay light
Green, steady · stored
Wired to
bus 1 · board 3 · ch 1

Ask to work on SR-03

Goes to Eszter Szabó · site administrator · no open fault on SR-03

Job

Then: choose a job.

Prototype

Overview · SR-03

Preview stateIn place

View as

This page

Purpose
One rack: overview, troubleshoot, settings.
Release
R1
First viewport
1 primary · 1 notice · 3 blocks