:00Thu 24 Sep

Dávid Horváth, Danutek technician account

Always on while R1 is trialled. Every action is logged under this named account; it is not a site user.

SR-01 · Reel rack A

Online SMT hall › SMT Line 2 · position 1

Technical details
Shape
5 tiers × 32 bays
Controller
CTRL-A01
Address
192.168.0.21
Floor label
POS-L2-01 · Station SMT-2 works on this rack

No job on SR-01

What you can do without a permit

You can identify the rack, read its sensors and try to reconnect it. Anything else needs a permit from the person who owns it.

Reels Janus doesn’t know

Every bay that reads a reel has a record but one: SR-01-T5-L30 holds R-2026-0077 with no record. It is difference 2 in COUNT-260714-A, where a supervisor decides it.

Bays

T5T4T3T2T1
  • Occupied
  • Empty
  • Reserved
  • Blinking red · an unexpected removal
Left tower off · Right tower green · blinking
Bays as a list
SR-01 bays
BayRecordSensorSize
SR-01-T2-L10R-2026-0175
PN-0402-100N · 4 000 pcs · an unexpected removal
Clear · since 14:217″
SR-01-T5-L22Empty · last bay of R-2026-0088, booked Missing by Janus 13:22Empty · dark7″
SR-01-T4-L31R-2026-0109
Being put in · Put-in not finished · Márta Kovács
Empty7″
SR-01-T3-L14R-2026-0042
PN-0603-10K · 5 000 pcs · stored 14:32
Reel7″
SR-01-T2-L28R-2026-0012
Reserved · WO-260714-07 · item 1
Reel7″
SR-01-T4-L12R-2026-0164
Reserved · WO-260714-07 · item 4
Reel7″
SR-01-T1-L25R-2026-0145
Reserved · WO-260714-07 · item 6
Reel7″

Showing a few of 160. Open Inventory to search and export every bay.

Connection path

  1. Janus serverjanus-smt-line2Running
  2. Rack networken5 · approved Mon 18 AugOnline
  3. Controller CTRL-A01192.168.0.21:502Online since 06:02 · 24 ms
  4. RS-485 bus 110 of 10 boards answerOK
  5. Sensors160 of 160 reportingOK

Identify

T5T4T3T2T1

Tiers light amber in turn, then the rack flashes twice. 3 s.

Tower lights

  • Left tower Off
    no rule matches
  • Right tower Green · blinking
    Rule 5 · put-in at T4-L31 since 14:20

Tower rules · the first match wins on each tower

Which readings count

When a reading counts

A reading counts only when the board answered, in the current connection, and newer than the last one Janus used. The controller saying “received” is not a reading.

SR-01 readings per board
Part of tierBoardReadingLast good readingCounts
Tier 1 · 1–32boards 1, 2OK0.4 s agoYes
Tier 2 · 1–32boards 3, 4OK0.7 s agoYes
Tier 3 · 1–32boards 5, 6OK0.3 s agoYes
Tier 4 · 1–32boards 7, 8OK0.6 s agoYes
Tier 5 · 1–32boards 9, 10OK0.2 s agoYes

Controller link

Response time
24ms
median of the last 60 reads
Reads per second
20
all 10 bay boards answering
Waiting to send
0
nothing waiting
Last full read
0.4s
complete
Technical details for IT
Model
HF-XGate2-P4 · serial 0410-202506-001-0201
Address
192.168.0.21:502 · switch port P1
Firmware
V2.01-2503 · reported by the controller 06:02
Boards
10 bay boards + tower board 11 · left tower out 1 · right tower out 2
Profile
janus.light-grid.xgate-tera-input.v1
  1. 14:32
    Stored · R-2026-0042 at T3-L14
    Márta Kovács · sensor confirmed
  2. 14:20
    Put-in started · R-2026-0109 at T4-L31
    Márta Kovács · not confirmed yet
  3. 13:05
    Counted · tier 5 · COUNT-260714-A
    Gábor Nagy · 2 differences
  4. 12:52
    Left tower yellow
    Janus · T5-L22 · right tower stays off
  5. 12:52
    Reel removed without a take-out · T5-L22
    Sensor · record says R-2026-0088 · sent to the Review queue
  6. 06:02
    Controller online
    Janus · after planned restart

Place

About place

Where the rack stands. It changes only through Move; bays and reels keep their records.

Where
SMT hall › SMT Line 2 · position 1
Floor label
POS-L2-01 · on the floor in front of the rack
Rack labels
RACK-SR-01 · one on each end
Home station
Station SMT-2 · its default working rack · set in Equipment
Switch port
P1 · seen 06:02
Place history · 1at SMT Line 2 · position 1 since Tue 9 Sep
  • SMT Line 2 · position 1
    since Tue 9 Sep · Set up there by Dávid Horváth

Setup

  1. IdentifyTue 9 Sep (done)
  2. NameSR-01 (done)
  3. Where it isSMT Line 2 · position 1 (done)
  4. Address192.168.0.21 (done)
  5. Shape5 × 32 (done)
  6. Check it answersPassed (done)
  7. Add to serviceTue 9 Sep (done)

Added to service by Dávid Horváth on Tue 9 Sep.

Storage and shape

About storage and shape

Bay widths and names change in Layout.

Holds
Reels
Shape
One side · 5 tiers × 32 bays · no double-height tiers
Bays
160 × 7″ · 2 boards of 16 per tier
Tower lights
2 · left end and right end, each set on its own
Names
SR-01-T{tier}-L{bay}

Rack behaviour

About rack behaviour

Written to the controller. Sensor timing for all racks is in Site rules.

%

Saved: 80 %

ms

Saved: 1000 ms

Versions · 13in use since Mon 22 Sep
  1. v13Eszter Szabó · Mon 22 Sep 09:10 · 1 changeIn useSee changes
  2. v12Gábor Szabó · Thu 18 Sep 15:40 · 1 changeSee changes
  3. v11Dávid Horváth · Mon 25 Aug · added to serviceSee changes

How often Janus reads each board

About how often janus reads each board

Set by Janus. A board with no answer is read less often.

SR-01 read pace per board
BoardReadsPaceActualWhy
boards 1, 2Tier 1Normal410 ms—
boards 3, 4Tier 2Normal420 ms—
boards 5, 6Tier 3Normal430 ms—
boards 7, 8Tier 4Normal440 ms—
boards 9, 10Tier 5Normal450 ms—

Retire this rack

About retire this rack

Empty it, switch it off, then retire it.

  1. Check3 things block this
  2. Emptying
  3. Switched off
  4. Retired
  • Blocks118 reels must be moved out first
  • Blocks3 reels reserved for WO-260714-07
  • Blocks1 Review item open at T5-L22

Retired racks keep their history; their bays are closed and can't be reopened. To use the rack again, set it up again.

Not available until the blockers are cleared.

In service

Alerts

Faults and blocked work stay here until fixed. Notices can be cleared.

SR-02 is limited

Bence Tóth is on itsince 09:41 · 4 h 51 min14:30 installation map v4 drafted by Dávid Horváth under permit · waiting to be applied

Tier 3, bays 1–16 are Unknown. Blocks 2 take-outs for WO-260714-09 and hides 310 pcs of PN-QFN32-MCU7. The rest of SR-02 works.

Troubleshoot SR-02Stays until fixed

Label not recognised

A Würth Elektronik label matched no code rule.

Eszter Szabó is told. Put the reel aside.

Put-in not finished

Reel R-2026-0109 is waiting for the sensor at SR-01-T4-L31: finish putting it in, or cancel.

Márta Kovács is on it.

Counter ReelSave is failing

Owner: line counter vendorsince 13:48

12 messages waiting. SMT Line 2 counters don't know about reels taken out since 13:48.

Handled by the site administrator.

Snapshot taken · 14:30

Verified · off-host copy 14:30. Snapshots every 15 min while Janus is busy.

Help

What the words mean

Language

Applies to this station only. Records keep the words they were written in.

SR-01-T5-L22

Tier 5 · bay 22 · 7″

Record

Empty

No reel on record

Sensor

Empty

0.4 s ago

Last bay of R-2026-0088: By: Janus · Missing delay · 13:22. Found it? Open in Review
Holds
Reels up to 7″
Bay light
Off · dark
Wired to
bus 1 · board 10 · ch 6

Ask to work on SR-01

Goes to Eszter Szabó · site administrator · no open fault on SR-01

Job

Then: choose a job.

Prototype

Overview · SR-01

Preview stateTower lamps work

View as

This page

Purpose
One rack: overview, troubleshoot, settings.
Release
R1
First viewport
1 primary · 1 notice · 3 blocks