SR-02 · High-capacity rack B
Technical details
- Shape
- 4 tiers × 32 bays
- Controller
- CTRL-B01
- Address
- 192.168.0.22
- Floor label
- POS-L2-02
- Permit
- PMT-260924-01 · Dávid Horváth · tier 3, bays 1–16
- Granted by
- Bence Tóth · 14:26 · ends when the fault closes
Your job · board swap on tier 3, bays 1–16
Until 18:00
Wiring version 4 is with Eszter Szabó · sent 14:30
Reels Janus doesn’t know
Every bay that reads a reel has a record. Tier 3, bays 1–16 can’t be read until board 5 answers.
Tier 3, bays 1–16 are Unknown · board 5 not reporting since 09:41
Unknown until board 5 reports. Put-ins skip these bays; a take-out there needs a scan.
What happened
The other 112 bays work normally; the left tower is yellow for tier 3. Dávid Horváth fitted a spare board at tier 3 at 14:18; it answers as board 10. He drafted wiring version 4 under his permit at 14:30: board 10 takes tier 3, bays 1–16. It waits for a site administrator to apply it.
Bays
- Occupied
- Empty
- Unknown
- Taken, awaiting the rack
- Presumed · not re-confirmed
- Permit · Dávid Horváth · until 18:00
Bays as a list
| Bay | Record | Sensor | Size |
|---|---|---|---|
| SR-02-T3-L03 | R-2026-0132 PN-0402-100N · 3 000 pcs | Unknown · since 09:41 | 7″ |
| SR-02-T3-L07 | R-2026-0131 PN-QFN32-MCU7 · 310 pcs | Unknown · since 09:41 | 7″ |
| SR-02-T3-L11 | R-2026-0134 PN-0603-10K · 2 000 pcs · taken, awaiting SR-02 since 10:12 | Unknown · since 09:41 | 7″ |
| SR-02-T2-L23 | R-2026-0160 PN-SOD123-1N4148 · 2 200 pcs | Reel | 7″ |
Showing a few of 128. Open Inventory to search and export every bay.
Waiting for the rack
How work goes on while a board is silent
Work goes on while board 5 is silent. A reel on record in these bays is taken out on screen guidance and a scan; nothing is booked until the settled read shows its bay Clear. Put-ins go to bays that report.
When the board reports again, Janus reads every bay of it before any light is set, and compares.
- R-2026-0134Taken, awaiting SR-02 PN-0603-10K · 2 000 pcsRecordSR-02-T3-L11 · scanned 10:12 by László Varga · to SMT Line 2SensorWaiting for the settled read
Who may work on this fault
- Permit
- PMT-260924-01 · Dávid Horváth
- Where
- SR-02 tier 3, bays 1–16 · boards 5 and 10
- May
- Ask boards again · light and check bays · read sensors · draft wiring
- Stays with
- A site administrator: applying wiring and everything else on SR-02
- Ends
- 18:00, or when the fault closes
- Granted
- Bence Tóth · fault owner · 14:26
Done under this permit
- 14:30Wiring version 4 drafted · board 10 → tier 3, bays 1–16waiting to be applied
- 14:30T3-L07 checked through board 10 · lit blueseen on his phone
- 14:27Board 5 asked again · no answer
Connection path
- Janus serverjanus-smt-line2Running
- Rack networken5 · approved Mon 18 AugOnline
- Controller CTRL-B01192.168.0.22:502Online since 06:02 · 26 ms
- RS-485 bus 17 of 8 bay boards answerBoard 5 · no answerCheck board 5 in Wiring
- Sensors112 of 128 reportingTier 3 · 1–16 unknown
Identify
Tiers light amber in turn, then the rack flashes twice. 3 s.
Tower lights
- Left tower YellowRule 7 · sensor data out of date · tier 3, bays 1–16 since 09:41
- Right tower Offno rule matches
Tower rules · the first match wins on each tower
Which readings count
When a reading counts
A reading counts only when the board answered, in the current connection, and newer than the last one Janus used. The controller saying “received” is not a reading.
| Part of tier | Board | Reading | Last good reading | Counts |
|---|---|---|---|---|
| Tier 1 · 1–32 | boards 1, 2 | OK | 0.4 s ago | Yes |
| Tier 2 · 1–32 | boards 3, 4 | OK | 0.2 s ago | Yes |
| Tier 3 · 1–16 | board 5 | No answer | 09:41 · 4 h 51 min ago | No — Unknown |
| Tier 3 · 17–32 | board 6 | OK | 0.5 s ago | Yes |
| Tier 4 · 1–32 | boards 7, 8 | OK | 0.4 s ago | Yes |
Technical details
- Connection epoch
- 41
- Last sequence, board 5
- 71 208 · 09:41:07
- Last sequence, other boards
- 90 110 – 90 117
Check sensors again
Board 5 · tier 3, bays 1–16 · nothing lights
Bay light test
Controller link
Technical details for IT
- Model
- HF-XGate2-P4 · serial 0410-202506-001-0202
- Address
- 192.168.0.22:502 · switch port P2
- Firmware
- V2.01-2503 · reported by the controller 06:02
- Boards
- 8 bay boards + tower board 9 · left tower out 1 · right tower out 2
- Profile
- janus.light-grid.xgate-tera-input.v1
- 14:30Wiring version 4 drafted · board 10 → tier 3, bays 1–16Dávid Horváth · permit PMT-260924-01 · waiting for a site administrator to apply
- 14:30Bay check through board 10 · T3-L07 lit blueSeen by Dávid Horváth on his phone · permit PMT-260924-01
- 14:27Board 5 asked again · no answerDávid Horváth · permit PMT-260924-01
- 14:26Permit granted · Dávid Horváth · tier 3, bays 1–16 until 18:00Bence Tóth · fault owner · PMT-260924-01
- 14:25Sensor check · no answer · board 5Eszter Szabó · 3 attempts · bays stay Unknown
- 14:20Board 10 answered · serves no tierController · spare board fitted by Dávid Horváth at 14:18
- 11:10Board 5 read less oftenJanus · automatic after 20 missed answers in a row
- 09:41Left tower yellowJanus · tier 3 unknown · right tower stays off
- 09:41Fault · sensors stopped · tier 3 · 1–16Janus · board 5 · no answer · still open · R-2026-0131 at T3-L07 unknown until the sensors report
- 06:02Controller onlineJanus · after planned restart
Place
About place
Where the rack stands. It changes only through Move; bays and reels keep their records.
- Where
- SMT hall › SMT Line 2 · position 2
- Floor label
- POS-L2-02 · on the floor in front of the rack
- Rack labels
- RACK-SR-02 · one on each end
- Home station
- None · operators switch to it by scanning RACK-SR-02
- Switch port
- P2 · seen 06:02
Place history · 2at SMT Line 2 · position 2 since Mon 1 Sep
- SMT Line 2 · position 2since Mon 1 Sep · Moved by Dávid Horváth · confirmed by Eszter SzabóEV-0612
- Store A · position 4Mon 25 Aug – Mon 1 Sep · Set up there by Dávid Horváth
Setup
- IdentifyMon 25 Aug (done)
- NameSR-02 (done)
- Where it isStore A · position 4 (done)
- Address192.168.0.22 (done)
- Shape4 × 32 (done)
- Check it answersPassed (done)
- Add to serviceMon 25 Aug (done)
Added to service by Dávid Horváth on Mon 25 Aug.
Storage and shape
About storage and shape
Bay widths and names change in Layout.
- Holds
- Reels
- Shape
- One side · 4 tiers × 32 bays · no double-height tiers
- Bays
- 128 × 7″ · 2 boards of 16 per tier
- Tower lights
- 2 · left end and right end, each set on its own
- Names
- SR-02-T{tier}-L{bay}
Rack behaviour
About rack behaviour
Written to the controller. Sensor timing for all racks is in Site rules.
Versions · 13
- v13Eszter Szabó · Mon 22 Sep 09:10 · 1 changeIn useSee changes
- v12Gábor Szabó · Thu 18 Sep 15:40 · 1 changeSee changes
- v11Dávid Horváth · Mon 25 Aug · added to serviceSee changes
Saved
Bay light brightness 80 % → 60 % on SR-02. The controller uses it the next time a bay lights; lights already on keep their brightness until they go off.
- By
- Dávid Horváth
- Saved
- 14:32 · Wed 24 Sep
- Version
- rack settings 13 → 14
Technical details
- Reference
- cmd_01J8Z7…M4RB
How often Janus reads each board
About how often janus reads each board
Set by Janus. A board with no answer is read less often.
| Board | Reads | Pace | Actual | Why |
|---|---|---|---|---|
| boards 1, 2 | Tier 1 | Normal | 400 ms | — |
| boards 3, 4 | Tier 2 | Normal | 410 ms | — |
| board 5 | Tier 3 · 1–16 | Slow · no answer | No answer | No answer since 09:41 |
| board 6 | Tier 3 · 17–32 | Normal | 420 ms | — |
| boards 7, 8 | Tier 4 | Normal | 410 ms | — |
Retire this rack
About retire this rack
Empty it, switch it off, then retire it.
- Check2 things block this
- Emptying
- Switched off
- Retired
- Blocks86 reels must be moved out first
- BlocksTier 3, bays 1–16 are Unknown: empty can’t be confirmed
Retired racks keep their history; their bays are closed and can't be reopened. To use the rack again, set it up again.
Not available until the blockers are cleared.