:00Thu 24 Sep

System

Strict · version 14

About Policies

Policies are the rules every rack and station decides by. Each change is a new version: it shows its impact on open work first, and going back is one more version through the same review.

Presets

Strict or Relaxed sets every preset value at once, in one version. A value set for the site, a rack, an item or a station overrides the preset where it applies: the first matching rule wins, from the most specific scope to the site.

What never relaxes

Approvals are off until switched on per action and scope. Fixed safeguards never relax. Publishing needs the policy grant; switching the preset needs it site-wide.

What each tower shows

Each tower shows the first rule that matches it, checked from the top. A rack’s two towers are checked separately, so one can show a put-in while the other shows a missing reel. Neo’s DP15 sets one colour and mode per signal; this ordered list with quiet hours is the concept’s proposal (Neo J05-Q7 is open), kept in R1 by the owner. Its timers are policy values: see Timers.

3 things to check before you apply

  • Rule 4 never shows on SR-03: its towers have no blue lamp.
  • Rule 8 never shows: rule 5 comes first for task in progress at this rack on the same towers.
  • Everywhere but SR-03: Help called at this rack (rule 4) and take-outs (rule 5) both show blue blink. A fault, a help call or a move must look unlike anything else.
  1. Rule 1: When Not in service yet
    Being set up or in handover. Its towers must not call the floor.
    Now: shows on SR-04 (both towers)
  2. Rule 2: When Rack being moved
    From the start of a move until the rack is scanned at its new place.
    Now: nothing to show
  3. Rule 3: When Fault on this rack
    A board, bay light or sensor reports a fault.
    Now: nothing to show
  4. Rule 4: When Help called at this rack
    Someone called for help here and nobody has taken it yet.
    Now: nothing to showRule 4 never shows on SR-03: its towers have no blue lamp.Everywhere but SR-03: Help called at this rack (rule 4) and take-outs (rule 5) both show blue blink. A fault, a help call or a move must look unlike anything else.
  5. Rule 5: When Task in progress at this rack
    A bay is lit for a put-in (green) or a take-out (blue).
    Now: shows on SR-01 right towerEverywhere but SR-03: Help called at this rack (rule 4) and take-outs (rule 5) both show blue blink. A fault, a help call or a move must look unlike anything else.
  6. Rule 6: When Reel missing
    A reel left its bay without a take-out, or was reported missing.
    Now: shows on SR-01 left tower · hidden on SR-01 right tower by rule 5
  7. Rule 7: When Sensor data out of date
    Some bays have no fresh sensor reading, so they are Unknown.
    Now: shows on SR-02 left tower
  8. Rule 8: When Task in progress at this rack
    A bay is lit for a put-in (green) or a take-out (blue).
    Now: nothing to show · hidden on SR-01 right tower by rule 5Rule 8 never shows: rule 5 comes first for task in progress at this rack on the same towers.
  9. Rule 9: Otherwise nothing else applies
    The rack is quiet. Always checked last.
    on both towers
    Now: shows on SR-02 right tower, SR-03 (both towers)

Towers have red, yellow, green, blue and white lamps; SR-03’s towers have red, yellow and green only. Blink is 500 ms on, 500 ms off, like a bay; slow blink is 1 s on, 1 s off. Drag a rule by its handle, or use the arrows.

Quiet hours

Use quiet hours
From – until

The hours the floor is quiet: towers calm down, faults and help calls still show.

Keep blinking

Then: from 22:00 to 06:00, tasks stop blinking and stay lit. Moves and help calls still blink.

Racks with their own rules

  • SR-01 · Reel rack A
    Left and right towers · red, yellow, green, blue and white lamps

    Follows the site’s tower rules.

  • SR-02 · High-capacity rack B
    Left and right towers · red, yellow, green, blue and white lamps

    Follows the site’s tower rules.

  • SR-03 · Line-side rack C
    Left and right towers · red, yellow and green lamps only (controller CTRL-C01)
  • SR-04 · Line-side rack D
    Side A and Side B towers · not in service yet

    Follows the site’s tower rules.

What the operator sees

Now · 14:32

The racks as they are at 14:32.

  • SR-01 · Reel rack A
    Online
    Details
    • Left Yellow steadyrule 6 · R-2026-0088 missing from SR-01-T5-L22
    • Right Green blinkrule 5 · put-in at SR-01-T4-L31
  • SR-02 · High-capacity rack B
    Limited
    Details
    • Left Yellow steadyrule 7 · tier 3 bays 1–16 Unknown since 09:41
    • Right Offnothing else applies
  • SR-03 · Line-side rack C
    Online
    Details
    • Left Offnothing else applies
    • Right Offnothing else applies
  • SR-04 · Line-side rack D
    Being set up
    Details
    • Side A Offrule 1 · being set up
    • Side B Offrule 1 · being set up

Try on SR-01

SR-01 shows left yellow steady, right green blink now.

Then: SR-01’s towers switch back by themselves after 10 s. Nothing is recorded.

Draft · 2 changes — 2 in Tower lights

Versions · 14Every change, who published it, and a way back
  1. v14Eszter Szabó · Tue 16 Sep 10:40 · 2 changesIn use
  2. v13Eszter Szabó · Tue 2 Sep 09:12 · 2 changes
  3. v12Eszter Szabó · Mon 1 Sep 11:05 · Strict preset · 3 changesSee changes
    • SR-02 sound: Site sound → Silent (quiet zone)
    • Missing delay at rack SR-02: 30 min → 1 h
    • DP11 at Station SMT-1: Not counted allowed

Publish 2 changes as version 15?

New decisions use it at once; open work keeps its version. Online racks change on their next read; ST-01 gets it when it reconnects.

Changes
ValueNowAfter
Tower lights
When help called at this rackwas Yellow blink · both towersnow Blue blink · both towers
New rule 8 · Task in progress at this rackwas —now White steady · nearest the bay

Impact preview

    Tower lights change on each rack’s next read, within 2 s. No tower changes what it shows right now.
    3 things to check in Tower lights. Rule 4 never shows on SR-03: its towers have no blue lamp. Rule 8 never shows: rule 5 comes first for task in progress at this rack on the same towers. Everywhere but SR-03: Help called at this rack (rule 4) and take-outs (rule 5) both show blue blink. A fault, a help call or a move must look unlike anything else. You can still publish.

    Switch the site to Strict as version 15?

    Every site-scope rule, grant template and approval switch changes at once: every command is decided under the whole old or the whole new preset, never a mix. Rules at a rack, item or station stay.

    No site value changes.

    Access that changes
    ActionStrictStrict
    Report issued; Report missing from Line or Receiving; Consume from Missing; Consume reversal; Adjust quantity by countSupervisor · approvals availableGranted to operators
    Void tentative issueSupervisorOperator at the recovery review; supervisor outside it
    Release a blocking condition (not Item unconfirmed)Supervisor, with a reasonA role the policy grants, with a reason
    Report missing from a bay by decision; Taken to line after an outageSupervisor · approvals availableGranted to operators
    Attestation: “Confirm all — nothing was touched”Supervisor with step-up; never the Unidentified operatorOperator, named sign-in only
    Take in for check; Cancel another person’s receipt or returnSupervisorGranted to operators
    Scrap; RestoreSupervisor · approvals availableSupervisor
    Issue from a Sensing disabled bay by decisionNot allowedSupervisor decision
    Switch a unit, tier or board into manual operationSupervisor with step-upUnchanged
    Approvals (maker–checker)Available per action and scope · offOff

    Impact preview

    • Open work
      Open tasks, removals and the SR-02 outage episode keep version 14. New ones use Strict.
    • Your draft
      Your unpublished edits stay on top of the new preset.

    Switching needs the policy grant and grant management over every affected scope, in this one command. A policy grant on a rack subtree publishes there, never a site-wide preset.

    Roll back to version 13?

    One step: version 15 gets the values of version 13. Version 14 stays in Versions. Open work keeps its version.

    Values that go back
    ValueNowAfter
    Soundwas Preset 2 · audiblenow Preset 1 · soft
    Buzzer forwas 3 snow 5 s

    Alerts

    Faults and blocked work stay here until fixed. Notices can be cleared.

    SR-02 is limited

    Bence Tóth is on itsince 09:41 · 4 h 51 min14:30 installation map v4 drafted by Dávid Horváth under permit · waiting to be applied

    Tier 3, bays 1–16 are Unknown. Blocks 2 take-outs for WO-260714-09 and hides 310 pcs of PN-QFN32-MCU7. The rest of SR-02 works.

    Troubleshoot SR-02Stays until fixed

    Label not recognised

    A Würth Elektronik label matched no code rule.

    Put-in not finished

    Reel R-2026-0109 is waiting for the sensor at SR-01-T4-L31: finish putting it in, or cancel.

    Counter ReelSave is failing

    Owner: line counter vendorsince 13:48

    12 messages waiting. SMT Line 2 counters don't know about reels taken out since 13:48.

    Snapshot taken · 14:30

    Verified · off-host copy 14:30. Snapshots every 15 min while Janus is busy.

    Choose working rack

    Scans and bay lights on this station use the working rack. Opening another rack never switches it.

    Racks

    Help

    What the words mean

    Language

    Applies to this station only. Records keep the words they were written in.

    Prototype

    Policies · System

    Preview stateTower draft with conflicts

    View as

    This page

    Purpose
    Presets, one row per decision, an impact preview and versions; tower lights.
    Release
    R1
    First viewport
    1 primary · 1 notice · 3 blocks