Label formats
About label formats
How supplier labels are read: one reader, one applicable format, for every scan at every station.
Exactly one enabled format may read a label. The order of the list is where a format is listed, not which one wins.
5 formats · 4 labels unread
4 labels no format reads · since 09:02
Registry revision 41
One format per label
Every enabled format is checked on every scan, and exactly one may read a label. Two that both read it overlap, even when they read it the same way: the list’s order never decides. Narrow one, or retire it.
Vendor pipe label
Active v3used for every scan since Tue 23 Sep 18:02
Shape v3 reads
Exactly 5 fields separated by “|”; field 1 is “VND”; field 4 is digits; field 5 is “VR-” + 6 digits.
Fields it records
- Part number
- field 2
- Lot
- field 3
- Quantity
- field 4
- Reel ID
- field 5
Unmapped fields are kept with every scan as raw evidence.
Working copy · v4
Without the VND marker, so labels printed without it read too.
Samples
What the samples must show
At least one sample that reads and one that must not. Every mapped field is shown by a sample that reads.
| # | Code | Expect | Result | Actions |
|---|---|---|---|---|
| 1 | VND|PN-420|LOT-8|250|VR-000871 | Reads · reel VR-000871 | Passes | |
| 2 | VND|PN-420|LOT-8 | Must not read · 3 fields | Passes |
Check
2 of 2 samples pass 2 labels of other formats read differently 6 stored labels read the same 0 read differently 3 unread labels now readable 0 ambiguous
It would read another format’s labels
- Würth Elektronik reel label: WE|885012206095|Q:4000|L:W2614-7731|DC:2614 → reel DC:2614
- Würth Elektronik reel label: WE|885012206095|Q:2000|L:W2615-0102|DC:2615 → reel DC:2615
- It changes how 2 labels of other formats read: refused in every preset.
Versions · 2
- v3ActiveEszter Szabó · Tue 23 Sep 18:02 · lot read from field 3In use
- v2SupersededEszter Szabó · Mon 1 Sep 10:15 · quantity field added
Try a code
This label can’t be read here.
Formats checked · 0 matched
- 1Vendor pipe label v3No VND markerNo match
- 2Renesas DI label v21 fields, the format has 8No match
- 3Videoton two-field v11 fields, the format has 2No match
- 4GS1 application identifiers v1No application identifiersNo match
- 5EIGP 114 · MH10 (Format 06) v1No Format 06 envelopeNo match
Labels no format reads
How these close
Each is a review item. A published version that reads it closes it.
- WE|885012206095|Q:4000|L:W2614-7731|DC:2614Station SMT-2 · 11:20 · Márta KovácsNot read
- WE|885012206095|Q:2000|L:W2615-0102|DC:2615Station SMT-2 · 11:24 · Márta KovácsNot read
- WE|744031100|Q:1500|L:W2609-4410|DC:2609Station SMT-2 · 11:31 · Márta KovácsNot read
- ZX-77781/unknownPDA-04 · 09:02 · Katalin HorváthNot read