:00Thu 24 Sep

Label rules

Rules that turn supplier labels into reels.

Later · not in R1Neo 0055 §36

The label-rule studio: rules that go Draft → Approved → In use, numeric priorities, a confidence ladder, custom regex and fallback reel IDs made from a label.

Not in R1
A format version is Active from its publish until a newer one supersedes it; there is no Draft → Approved → Active chain (J07 §3). Exactly one enabled format may read a label and order never decides (0067), from a closed set of kinds with no scripting, and reel IDs come only from labels (0052 §6).
R1 instead
Label formats: a working copy is published after a check of its samples and every stored raw code, and Try reads a code exactly as a station does. Open Label rules

3 Würth Elektronik labels not recognised · Station SMT-2 · since 11:20

The scans are saved with the draft below. Márta Kovács typed those reels in by hand.

A picture of the studio before R1

Nothing here can be changed. You can still read codes with it.

Draft · not publishedfrom 3 saved scans on Station SMT-2

  1. Draft
  2. Approved
  3. In use
  4. Retired

Example reads

5 fields

Test examples

6 of 6 pass

No new conflict

1 tie with Vendor pipe label

Publish

Waits for the tie

Read by Würth Elektronik reel label

StrongNo review needed
  1. 1@0WEMatch marker
  2. @2|
  3. 2@3885012206095Manufacturer PN885012206095
  4. @15|
  5. 3@16Q:4000Quantity4 000 pcs
  6. @22|
  7. 4@23L:W2614-7731LotW2614-7731
  8. @35|
  9. 5@36DC:2614Date code2614 · 2026 wk 14

␞ Record separator 0x1E␝ Group separator 0x1D␄ End of transmission 0x0443 bytes · 0 control characters

Fields to record

Fields to record
FieldValueFrom
Manufacturer PN885012206095Label
Quantity4 000 pcsLabel
LotW2614-7731Label
Date code2614 · 2026 wk 14Label
Part IDPN-0402-100NOther part number
ManufacturerWürth ElektronikRule default

Rules that looked at this code

  1. 1
    Würth Elektronik reel label Draft · P75
    Selected · all 5 segments matched
    Strong
  2. 2
    Vendor pipe label v3 P80
    Rejected · 5 segments, rule expects 4
    Weak match
  3. 3
    ANSI MH10.8.2 Built-in · P10
    No envelope
    None
  4. 4
    GS1 application identifiers Built-in · P10
    No AI brackets
    None

Ranked by match, then priority. A tie for first stops for review.

Conflicts

1 tie blocks publishing

Example 4 has no date code. Both rules read it equally well, so it would stop for review.

WE|885012206095|Q:4000|L:W2614-7731

This draft · P75

Strong match, one warning

Manufacturer PN
885012206095
Quantity
4 000
Date code
Missing

Vendor pipe label v3 · P80

Weak match

Part ID
885012206095
Lot
Q:4000
Quantity
Not a number

Last 30 days (2 990 scans): no scan changes rule. The 3 saved Würth scans match this draft.

Test examples

Saved test example codes
#CodeExpectResult
1WE|885012206095|Q:4000|L:W2614-7731|DC:2614Match · 5 fieldsPassed
2WE|885012206095|Q:2000|L:W2615-0102|DC:2615Match · qty 2 000Passed
3WE|744031100|Q:1500|L:W2609-4410|DC:2609Match · MPN 744031100Passed
4WE|885012206095|Q:4000|L:W2614-7731Match · warn: no date codePassed
5VND|PN-420|LOT-8|250Must not matchPassed · no match
6WE|885012206095Must not matchPassed · no match
Defaults for fields the label leaves out

Recorded as “Rule default”.

Manufacturer
Würth Elektronik
Date code format
YYWW
Look up from an integration

Finds the part by manufacturer PN in SAP S/4 material lookup. If SAP doesn't answer: warn and use Janus part numbers.

Technical details
Pattern
^WE\|([0-9]{6,14})\|Q:([0-9]+)\|L:([A-Z0-9-]+)(?:\|DC:([0-9]{4}))?$
Draft version
version 3 · new
History
0 of 50 versions kept

Alerts

Faults and blocked work stay here until fixed. Notices can be cleared.

SR-02 is limited

Bence Tóth is on itsince 09:41 · 4 h 51 min14:30 installation map v4 drafted by Dávid Horváth under permit · waiting to be applied

Tier 3, bays 1–16 are Unknown. Blocks 2 take-outs for WO-260714-09 and hides 310 pcs of PN-QFN32-MCU7. The rest of SR-02 works.

Troubleshoot SR-02Stays until fixed

Label not recognised

A Würth Elektronik label matched no code rule.

Put-in not finished

Reel R-2026-0109 is waiting for the sensor at SR-01-T4-L31: finish putting it in, or cancel.

Counter ReelSave is failing

Owner: line counter vendorsince 13:48

12 messages waiting. SMT Line 2 counters don't know about reels taken out since 13:48.

Snapshot taken · 14:30

Verified · off-host copy 14:30. Snapshots every 15 min while Janus is busy.

Choose working rack

Scans and bay lights on this station use the working rack. Opening another rack never switches it.

Racks

Help

What the words mean

Language

Applies to this station only. Records keep the words they were written in.

ANSI MH10.8.2

Built-in · ISO 15434 Format 06 envelope · P10 · in use

Can't be edited. A site rule that matches as well wins.
ANSI MH10.8.2 fields
IdentifierField
PPart ID (customer)
1PManufacturer PN
QQuantity
1TLot
9D / 10DDate code
S / 3SSerial
4LCountry of origin

1 840 matches in 30 days · last miss Tue 23 Sep, 16:02 (damaged TI label).

GS1 application identifiers

Built-in · P10 · in use

Can't be edited. Retire it to stop using it.
GS1 application identifiers fields
AIField
(01)GTIN
(10)Lot
(11)Manufactured on
(17)Expiry date
(21)Serial
(30)Quantity

610 matches in 30 days · no misses this week.

Prototype

Label rules · before R1

Preview stateLabel rules before R1

Later · not in R1

View as

This page

Purpose
Label formats: active and working copies, tried on a reader, published with step-up.
Release
R1
First viewport
1 primary · 1 notice · 3 blocks