:00Thu 24 Sep

Equipment

About Connections

The rack network, the server’s ports and the devices that reach Janus.

Ports and addresses are the host’s, set in the Janus Service CLI; this page shows them and never changes them.

Needs action

  1. 1
    ST-01 is reconnecting
    Slots show Unknown until read. No action needed.
    Details
    1. Answered14:31:30 (done)
    2. Same controllerserial …0204 (done)
    3. Reading slots31 of 48
    4. Onlinenext
  2. 2
    New server port en7 · USB Ethernet
    Plugged in 13:50 · 10.40.2.18/24. Janus sends nothing on it until plant IT decides its use on the host.

Rack network

Last search
14:32:04 · next 14:32:34
Automatic reconnect
On
Answering
3 of 4 in service
Drops today
2 · SR-03 06:40, ST-01 07:12
Rack network devices
DeviceAddressStatusLast answerResponseOpen
In service · 4
Being set up · 2 · Rack setup
Not set up · 3

Server ports

Who sets a server port

A port’s use is the host’s. A maintenance-group member sets it on this computer in the Janus Service CLI; Janus shows what the host has and never changes it.

An isolated rack switch or VLAN is recommended, not required.

The Janus Service CLI step
janus-service ports show
janus-service ports set en7 --use none
  • Rack network
    en5 · 192.168.0.253/24
    Switch port P24
    Used for
    Rack controllers · Modbus TCP, port 502
    Allowed and Never
    Allowed
    • Search for controllers every 30 s
    • Follow a known controller by its serial to another switch port or address
    • Set a new controller’s address from the pool, in Rack setup
    Never
    • Hand out addresses, forward traffic or change the switch
    • Change the address of a controller in service, except inside Move or Replace controller on its rack
    • Accept phones, handhelds or terminals
    In useSet in the Janus Service CLI · Gábor Szabó · Mon 18 Aug
  • Office network
    en0 · 192.168.10.24/24
    Used for
    Handhelds, line terminals, phones and office PCs open Janus · HTTPS, port 8443
    Allowed and Never
    Allowed
    Serve Janus at https://janus-smt-line2.local:8443
    Never
    Search for controllers or offer devices for setup
    In usePhone access is set in System
  • USB Ethernet
    en7 · 10.40.2.18/24
    Plugged in today 13:50
    Used for
    Nothing yet
    Never
    Never
    Anything sent until a use is chosen
    New · not used
Wi-Fi · en1 · not connected · not used

Stations and devices

9 devices reach JanusPDA-03 late since 14:30:57Managed in Racks and devices

Address pool

  • Used · A01 B01 C01 S01 · …0344
  • Offered to …0311
  • Free
Factory default
192.168.0.10 · never kept
Outside the pool
.51 .52 .100 .110 · not set up
Given out by
Rack setup, one controller at a time
Range set by
The Janus Service CLI on the host
janus-service ports set en5 --pool 192.168.0.20-39

Alerts

Faults and blocked work stay here until fixed. Notices can be cleared.

SR-02 is limited

Bence Tóth is on itsince 09:41 · 4 h 51 min14:30 installation map v4 drafted by Dávid Horváth under permit · waiting to be applied

Tier 3, bays 1–16 are Unknown. Blocks 2 take-outs for WO-260714-09 and hides 310 pcs of PN-QFN32-MCU7. The rest of SR-02 works.

Troubleshoot SR-02Stays until fixed

Label not recognised

A Würth Elektronik label matched no code rule.

Put-in not finished

Reel R-2026-0109 is waiting for the sensor at SR-01-T4-L31: finish putting it in, or cancel.

Counter ReelSave is failing

Owner: line counter vendorsince 13:48

12 messages waiting. SMT Line 2 counters don't know about reels taken out since 13:48.

Snapshot taken · 14:30

Verified · off-host copy 14:30. Snapshots every 15 min while Janus is busy.

Choose working rack

Scans and bay lights on this station use the working rack. Opening another rack never switches it.

Racks

Help

What the words mean

Language

Applies to this station only. Records keep the words they were written in.

CTRL-A01

SR-01 · Reel rack A · SMT Line 2 · position 1 · 192.168.0.21:502

Online since
06:02
Response today
19–41 ms · now 24 ms
Drops today
0
MAC
C0:D3:91:F0:AE:21
Serial
0410-202506-001-0201
Model
HF-XGate2-P4
Firmware
V2.01-2503 · reported 06:02
Switch port
P1 · seen 06:02, the same as at setup
Place and moves · SR-01

CTRL-B01

SR-02 · High-capacity rack B · SMT Line 2 · position 2 · 192.168.0.22:502

Network is fine. Board 5 is silent.

Tier 3, bays 1–16 show Unknown since 09:41. Board 5 is a wiring or board fault on the rack, not a network fault.
Online since
06:02
Response today
20–44 ms · now 26 ms
Drops today
0
MAC
C0:D3:91:F0:AE:22
Serial
0410-202506-001-0202
Model
HF-XGate2-P4
Firmware
V2.01-2503 · reported 06:02
Switch port
P2 · seen 06:02 · since the move of Mon 1 Sep (was P8 at Store A)
Troubleshoot SR-02

CTRL-C01

SR-03 · Line-side rack C · SMT Line 1 · position 1 · 192.168.0.23:502

Online since
06:40
Response today
22–58 ms · now 31 ms
Drops today
1

History today

  1. 06:40:12
    No answer for 3 tries
  2. 06:40:13
    Reconnected automatically
    same serial · took 1.2 s
MAC
00:1A:79:3C:07:77
Serial
R03-2025-0077
Model
Rack03
Firmware
R3-1.4.2 · expected, the controller doesn’t report it
Switch port
P3 · seen 06:40
Place and moves · SR-03

CTRL-S01

ST-01 · Stencil tower · Stencil room · position 1 · 192.168.0.24:502

  1. Answered14:31:30 (done)
  2. Same controllerserial …0204 (done)
  3. Reading slots31 of 48
  4. Onlinenext

Slots show Unknown until read.

MAC
C0:D3:91:F0:B1:02
Serial
0410-202506-001-0204
Model
HF-XGate2-P4
Firmware
V2.01-2503 · reported 06:02
Switch port
P4 · last seen 07:11
Open parked racks

…0311

New controller · to become SR-04 · Line-side rack D

Dávid Horváth is setting it up · at Address. The Address step moves it from the factory default to 192.168.0.25.

Address now
192.168.0.10:502 · factory default
Offered
192.168.0.25
Response
22 ms
MAC
C0:D3:91:F0:A8:73
Serial
0410-202506-001-0311
Model
HF-XGate2-P4
Firmware
V2.01-2503
Switch port
P6
Continue setup

…0344

Draft SR-05 · Stencil rack E · setup paused

Paused by Dávid Horváth at 13:52, at Shape. The Address step already moved it into the pool.

Address now
192.168.0.26:502 · from the pool
Response
25 ms
MAC
C0:D3:91:F0:A9:44
Serial
0410-202506-001-0344
Model
HF-XGate2-P4
Firmware
V2.01-2503
Switch port
P7
Continue setup

DG-IOTW-LANWIFI

Gateway · 192.168.0.51 and 192.168.0.52

Two addresses, one serial

Usually one device on two network ports, or a copied setup. It can’t be set up until one address is gone.
MAC
28:3D:E8:F0:A8:72, …:73
Serial
DG-2409-11873 · on both
First heard
today 13:40
Commands sent
None
Review in Rack setup

Unknown device

192.168.0.110 · not a rack controller

It answers on the network but not as a rack controller. No commands are sent to it.

MAC
3C:52:82:19:7E:01
Maker (from MAC)
HP Inc.
First heard
Mon 22 Sep
Last heard
2 min ago

Unknown XGate

192.168.0.100 · never set up on this site

Answered as an XGate controller until Tue 23 Sep. It was never set up here.

MAC
00:11:22:33:44:4C
Last heard
Tue 23 Sep 16:04
Commands sent
None

Pause automatic reconnect on en5?

A controller that drops or changes address stays offline until someone reconnects it here. Search continues.

Recorded with your name in Activity.

Write at least 4 characters.

Prototype

Connections · Equipment

Preview stateReconnecting

View as

This page

Purpose
The rack network, ports and devices; set in the Janus Service CLI.
Release
R1
First viewport
1 primary · 1 notice · 3 blocks