:00Thu 24 Sep

Dávid Horváth, Danutek technician account

Always on while R1 is trialled. Every action is logged under this named account; it is not a site user.

Later · not in R1Neo 0032 §24; PRD §1.4

Stencil racks: stencils stored by slot, their tower, and taking a stencil out to a printer

Not in R1
Neo keeps the model shape for stencils but defers their qualification and journeys until after R1: release 1 stores reels only
R1 instead
Reel racks only. Stencils stay where the site keeps them today, outside Janus Open Equipment

ST-01 · Stencil tower

Offline since 07:12 Stores › Stencil room · position 1

Technical details
Shape
4 tiers × 12 slots
Controller
CTRL-S01
Address
192.168.0.24
Floor label
POS-ST-01

No job on ST-01

What you can do without a permit

You can identify the rack, read its sensors and try to reconnect it. Anything else needs a permit from the person who owns it.

Ask to work on ST-01

Wiring map

CTRL-S01HF-XGate2-P4192.168.0.24
Firmware
V2.01-2503 · reported 06:02
Built
4 tiers × 12 · 4 bay boards + tower board 5
Towers
Top · on board 5
Bus 1
No answer since 07:12
  • No answer · controller offline
  • Unknown

Can’t compare

CTRL-S01 is offline since 07:12

The wiring can be compared once it answers. Wiring version 1 stays in use.

Tiers, boards and towers

ST-01 boards per tier and tower
TierSensor boardsLight boardsSlotsStateLast checked
T4Bus 1 · 4Bus 1 · 412No answer07:10 · before it went offline
T3Bus 1 · 3Bus 1 · 312No answer07:10 · before it went offline
T2Bus 1 · 2Bus 1 · 212No answer07:10 · before it went offline
T1Bus 1 · 1Bus 1 · 112No answer07:10 · before it went offline
Tower light—Bus 1 · 5 out 1—No answer07:10
  1. 07:12
    Controller offline · last compared 07:10, no differences
    Janus
  2. Fri 12 Sep
    Version 1 turned on · rack added to service
    Dávid Horváth · Rack setup

Offline Wiring version 1 stays in use
Can’t compare while CTRL-S01 is offline · since 07:12

Alerts

Faults and blocked work stay here until fixed. Notices can be cleared.

SR-02 is limited

Bence Tóth is on itsince 09:41 · 4 h 51 min14:30 installation map v4 drafted by Dávid Horváth under permit · waiting to be applied

Tier 3, bays 1–16 are Unknown. Blocks 2 take-outs for WO-260714-09 and hides 310 pcs of PN-QFN32-MCU7. The rest of SR-02 works.

Troubleshoot SR-02Stays until fixed

Label not recognised

A Würth Elektronik label matched no code rule.

Eszter Szabó is told. Put the reel aside.

Put-in not finished

Reel R-2026-0109 is waiting for the sensor at SR-01-T4-L31: finish putting it in, or cancel.

Márta Kovács is on it.

Counter ReelSave is failing

Owner: line counter vendorsince 13:48

12 messages waiting. SMT Line 2 counters don't know about reels taken out since 13:48.

Handled by the site administrator.

Snapshot taken · 14:30

Verified · off-host copy 14:30. Snapshots every 15 min while Janus is busy.

Help

What the words mean

Language

Applies to this station only. Records keep the words they were written in.

Prototype

Wiring · ST-01

Preview stateTechnician view

View as

This page

Purpose
Boards and channels per tier.
Release
R1
First viewport
1 primary · 1 notice · 3 blocks