:00Thu 24 Sep

Dávid Horváth, Danutek technician account

Always on while R1 is trialled. Every action is logged under this named account; it is not a site user.

SR-02 · High-capacity rack B

Limited · tier 3 bays 1–16 unknown since 09:41 SMT hall › SMT Line 2 · position 2

Technical details
Shape
4 tiers × 32 bays
Controller
CTRL-B01
Address
192.168.0.22
Floor label
POS-L2-02

No job on SR-02

What you can do without a permit

You can identify the rack, read its sensors and try to reconnect it. Anything else needs a permit from the person who owns it.

Ask to work on SR-02

Wiring map

CTRL-B01HF-XGate2-P4192.168.0.22
Firmware
V2.01-2503
Can handle
16 boards × 16 bays
Built
4 tiers × 32 · 8 bay boards + tower board 9
Towers
Left · right · on board 9
Bus 1
7 of 8 bay boards answer
  • OK
  • Difference or draft change
  • Occupied bay
  • Unknown · board with no answer

2 differences

  1. Board 5 does not answer
    Tier 3, bays 1–16 have no sensor readings and no lights since 09:41.

    From controller3 read requests failed at 14:25

  2. Board 10 answers but serves no tier
    First answered at 14:20 on its factory address, 10. Using it as board 10 in the wiring needs no readdressing.

    Dávid Horváthfitted a spare board at tier 3 left · 14:18

Tiers, boards and towers

SR-02 boards per tier and tower
TierSensor boardsLight boardsBaysStateLast checked
T4Bus 1 · 7, 8Bus 1 · 7, 832OKMon 25 Aug · seen by a person
T3Bus 1 · 5, 6Bus 1 · 5, 632Board 5 · no answer14:25 · no answer from board 5
T2Bus 1 · 3, 4Bus 1 · 3, 432OKMon 25 Aug · seen by a person
T1Bus 1 · 1, 2Bus 1 · 1, 232OKMon 25 Aug · seen by a person
Left tower—Bus 1 · 9 out 1—OKMon 25 Aug · seen by a person
Right tower—Bus 1 · 9 out 2—OKMon 25 Aug · seen by a person
Board 10Bus 1 · 10——Serves no tier14:20 · first answered
Versions · 3in use since Wed 17 Sep
  1. v3Eszter Szabó · Wed 17 Sep · 2 changesIn useSee changes
  2. v2Eszter Szabó · Fri 12 Sep · 1 changeSee changes
  3. v1Dávid Horváth · Mon 25 Aug · added to serviceSee changes
  1. 14:25
    Sensor check · no answer · board 5
    Eszter Szabó · 3 attempts
  2. 14:20
    Board 10 answered · serves no tier
    Controller
  3. 14:18
    Spare board fitted · tier 3 left
    Dávid Horváth · at the rack
  4. 09:41
    Board 5 stopped answering · tier 3, bays 1–16 Unknown
    Janus
  5. Wed 17 Sep
    Version 3 turned on
    Eszter Szabó

Draft · no changes yet · 2 differences to resolve
From wiring version 3 · still current · Dávid Horváth, 14:32

A site administrator applies it.

Draft and version 4

Version 4 was applied by Gábor Szabó at 14:31.

Draft

T3 bays 1–16
board 10
Board 5
Unassigned

Version 4

T3 bays 1–16
board 5
Board 10
Spare

Alerts

Faults and blocked work stay here until fixed. Notices can be cleared.

SR-02 is limited

Bence Tóth is on itsince 09:41 · 4 h 51 min14:30 installation map v4 drafted by Dávid Horváth under permit · waiting to be applied

Tier 3, bays 1–16 are Unknown. Blocks 2 take-outs for WO-260714-09 and hides 310 pcs of PN-QFN32-MCU7. The rest of SR-02 works.

Troubleshoot SR-02Stays until fixed

Label not recognised

A Würth Elektronik label matched no code rule.

Eszter Szabó is told. Put the reel aside.

Put-in not finished

Reel R-2026-0109 is waiting for the sensor at SR-01-T4-L31: finish putting it in, or cancel.

Márta Kovács is on it.

Counter ReelSave is failing

Owner: line counter vendorsince 13:48

12 messages waiting. SMT Line 2 counters don't know about reels taken out since 13:48.

Handled by the site administrator.

Snapshot taken · 14:30

Verified · off-host copy 14:30. Snapshots every 15 min while Janus is busy.

Help

What the words mean

Language

Applies to this station only. Records keep the words they were written in.

Prototype

Wiring · SR-02

Preview stateDraft · differences

View as

This page

Purpose
Boards and channels per tier.
Release
R1
First viewport
1 primary · 1 notice · 3 blocks