:00Thu 24 Sep

Dávid Horváth, Danutek technician account

Always on while R1 is trialled. Every action is logged under this named account; it is not a site user.

SR-04 · Line-side rack D

In service · 40 reels to adopt SMT hall › SMT Line 2 · position 3

Technical details
Shape
2 sides × 4 tiers × 16 bays · tier 4 double height
Controller
…0311
Address
192.168.0.25
Floor label
POS-L2-03

No job on SR-04

What you can do without a permit

You can identify the rack, read its sensors and try to reconnect it. Anything else needs a permit from the person who owns it.

Ask to work on SR-04

Wiring map

…0311HF-XGate2-P4192.168.0.25
Built
2 sides × 4 × 16
Boards
8 bay boards · 4 per side + tower board 9
Towers
Side A · side B · on board 9
Bus 1
8 of 8 bay boards answer

Side A

Board 4A-T4
Bays 1–16
double height
Board 3A-T3
Bays 1–16
Board 2A-T2
Bays 1–16
Board 1A-T1
Bays 1–16
Board 9Side A towerout 1 · off

Side B

Board 8B-T4
Bays 1–16
double height
Board 7B-T3
Bays 1–16
Board 6B-T2
Bays 1–16
Board 5B-T1
Bays 1–16
Board 9Side B towerout 2 · off
  • Planned in setup · not checked yet
  • Double-height tier

Tiers, boards and towers

SR-04 tiers and boards per side
TierSide ASide BBays per sideHeight
T4Bus 1 · 4Bus 1 · 816Double
T3Bus 1 · 3Bus 1 · 716Single
T2Bus 1 · 2Bus 1 · 616Single
T1Bus 1 · 1Bus 1 · 516Single
TowersBus 1 · 9 out 1Bus 1 · 9 out 2——
  1. 14:24
    Wiring planned · 8 bay boards + tower board 9
    Dávid Horváth · Rack setup · not checked yet

Matches Wiring version 1 is in use and matches the controller
Checked 14:31 in setup · 128 of 128 sensors answer where expected

Alerts

Faults and blocked work stay here until fixed. Notices can be cleared.

SR-02 is limited

Bence Tóth is on itsince 09:41 · 4 h 51 min14:30 installation map v4 drafted by Dávid Horváth under permit · waiting to be applied

Tier 3, bays 1–16 are Unknown. Blocks 2 take-outs for WO-260714-09 and hides 310 pcs of PN-QFN32-MCU7. The rest of SR-02 works.

Troubleshoot SR-02Stays until fixed

Label not recognised

A Würth Elektronik label matched no code rule.

Eszter Szabó is told. Put the reel aside.

Put-in not finished

Reel R-2026-0109 is waiting for the sensor at SR-01-T4-L31: finish putting it in, or cancel.

Márta Kovács is on it.

Counter ReelSave is failing

Owner: line counter vendorsince 13:48

12 messages waiting. SMT Line 2 counters don't know about reels taken out since 13:48.

Handled by the site administrator.

Snapshot taken · 14:30

Verified · off-host copy 14:30. Snapshots every 15 min while Janus is busy.

Help

What the words mean

Language

Applies to this station only. Records keep the words they were written in.

Prototype

Wiring · SR-04

Preview stateTechnician view

View as

This page

Purpose
Boards and channels per tier.
Release
R1
First viewport
1 primary · 1 notice · 3 blocks