:00Thu 24 Sep

SR-02 · High-capacity rack B

Limited · tier 3 bays 1–16 unknown since 09:41 SMT hall › SMT Line 2 · position 2

Technical details
Shape
4 tiers × 32 bays
Controller
CTRL-B01
Address
192.168.0.22
Floor label
POS-L2-02
Viewing · working rack stays SR-01

Wiring map

CTRL-B01HF-XGate2-P4192.168.0.22
Firmware
V2.01-2503
Can handle
16 boards × 16 bays
Built
4 tiers × 32 · 8 bay boards + tower board 9
Towers
Left · right · on board 9
Bus 1
7 of 8 bay boards answer
  • OK
  • Difference or draft change
  • Occupied bay
  • Unknown · board with no answer

2 differences

  1. Board 5 does not answer
    Tier 3, bays 1–16 have no sensor readings and no lights since 09:41.

    From controller3 read requests failed at 14:25

  2. Board 10 answers but serves no tier
    First answered at 14:20 on its factory address, 10. Using it as board 10 in the wiring needs no readdressing.

    Dávid Horváthfitted a spare board at tier 3 left · 14:18

Tiers, boards and towers

SR-02 boards per tier and tower
TierSensor boardsLight boardsBaysStateLast checked
T4Bus 1 · 7, 8Bus 1 · 7, 832OKMon 25 Aug · seen by a person
T3Bus 1 · 5, 6Bus 1 · 5, 632Board 5 · no answer14:25 · no answer from board 5
T2Bus 1 · 3, 4Bus 1 · 3, 432OKMon 25 Aug · seen by a person
T1Bus 1 · 1, 2Bus 1 · 1, 232OKMon 25 Aug · seen by a person
Left tower—Bus 1 · 9 out 1—OKMon 25 Aug · seen by a person
Right tower—Bus 1 · 9 out 2—OKMon 25 Aug · seen by a person
Board 10Bus 1 · 10——Serves no tier14:20 · first answered
Versions · 3in use since Wed 17 Sep
  1. v3Eszter Szabó · Wed 17 Sep · 2 changesIn useSee changes
  2. v2Eszter Szabó · Fri 12 Sep · 1 changeSee changes
  3. v1Dávid Horváth · Mon 25 Aug · added to serviceSee changes
  1. 14:25
    Sensor check · no answer · board 5
    Eszter Szabó · 3 attempts
  2. 14:20
    Board 10 answered · serves no tier
    Controller
  3. 14:18
    Spare board fitted · tier 3 left
    Dávid Horváth · at the rack
  4. 09:41
    Board 5 stopped answering · tier 3, bays 1–16 Unknown
    Janus
  5. Wed 17 Sep
    Version 3 turned on
    Eszter Szabó

Draft · no changes yet · 2 differences to resolve
From wiring version 3 · still current · Eszter Szabó, 14:32

Apply wiring version 4 to SR-02?

New work on tier 3, bays 1–16 stops first; the rest of SR-02 stays in service. Those bays wait until the new wiring is turned on.

  • Open
    2 differences stay open after applying. They don’t block it.
    Still to resolve

If the wiring changes elsewhere first, this draft is not applied and is kept.

Turn on SR-02 with wiring version 4?

Tier 3, bays 1–16 keep their names and their 4 reels on record, including R-2026-0131 at T3-L07, with no presumption: a changed map is band Beyond, and a count of those 16 bays is raised for a supervisor. T3-L12 reads a reel with no record: an Unknown placement until someone pulls it, scans it and puts it in.

Discard this draft?

The draft changes are removed. Version 3 stays in use. Checks stay in the history.

Assign board 10 to a tier

Changes the draft only.

The board it replaces becomes unassigned.

Draft and version 4

Version 4 was applied by Gábor Szabó at 14:31.

Draft

T3 bays 1–16
board 10
Board 5
Unassigned

Version 4

T3 bays 1–16
board 5
Board 10
Spare

Alerts

Faults and blocked work stay here until fixed. Notices can be cleared.

SR-02 is limited

Bence Tóth is on itsince 09:41 · 4 h 51 min14:30 installation map v4 drafted by Dávid Horváth under permit · waiting to be applied

Tier 3, bays 1–16 are Unknown. Blocks 2 take-outs for WO-260714-09 and hides 310 pcs of PN-QFN32-MCU7. The rest of SR-02 works.

Troubleshoot SR-02Stays until fixed

Label not recognised

A Würth Elektronik label matched no code rule.

Put-in not finished

Reel R-2026-0109 is waiting for the sensor at SR-01-T4-L31: finish putting it in, or cancel.

Counter ReelSave is failing

Owner: line counter vendorsince 13:48

12 messages waiting. SMT Line 2 counters don't know about reels taken out since 13:48.

Snapshot taken · 14:30

Verified · off-host copy 14:30. Snapshots every 15 min while Janus is busy.

Choose working rack

Scans and bay lights on this station use the working rack. Opening another rack never switches it.

Racks

Help

What the words mean

Language

Applies to this station only. Records keep the words they were written in.

Prototype

Wiring · SR-02

Preview stateDraft · differences

View as

This page

Purpose
Boards and channels per tier.
Release
R1
First viewport
1 primary · 1 notice · 3 blocks