:00Thu 24 Sep

SR-03 · Line-side rack C

Being moved by Dávid Horváth · until 14:50

Being moved · no put-in or take-out until it is in place SMT Line 1 · position 1 → SMT Line 1 · position 3

Technical details
Shape
3 tiers × 16 bays · tier 2 double height
Controller
CTRL-C01
Address
192.168.0.23
Floor label
POS-L1-01 · Station SMT-1 works on this rack
Move permit
PMT-260924-02 · started 14:20 · no offline alarm until 14:50
Being moved · can’t be a working rack until it is in place

Wiring map

CTRL-C01Rack03192.168.0.23
Firmware
R3-1.4.2 · expected, not reported
Built
3 tiers × 16 · 3 bay boards + tower board 4
Towers
Left · right · on board 4
Bus 1
3 of 3 bay boards answer
  • OK
  • Occupied bay
  • Double-height tier

No differences

48 of 48 sensors answer where expected

Left tower on output 1, right tower on output 2.

Tiers, boards and towers

SR-03 boards per tier and tower
TierSensor boardsLight boardsBaysStateLast checked
T3Bus 1 · 3Bus 1 · 316OKMon 15 Sep · seen by a person
T2Bus 1 · 2Bus 1 · 216OKMon 15 Sep · seen by a person
T1Bus 1 · 1Bus 1 · 116OKMon 15 Sep · seen by a person
Left tower—Bus 1 · 4 out 1—OKMon 15 Sep · seen by a person
Right tower—Bus 1 · 4 out 2—OKMon 15 Sep · seen by a person
  1. Mon 15 Sep
    Version 2 turned on · right tower moved to output 2
    Eszter Szabó
  2. Thu 11 Sep
    Version 1 turned on · rack added to service
    Dávid Horváth · Rack setup

Matches Wiring version 2 is in use and matches the controller
Last compared 14:31

Alerts

Faults and blocked work stay here until fixed. Notices can be cleared.

SR-02 is limited

Bence Tóth is on itsince 09:41 · 4 h 51 min14:30 installation map v4 drafted by Dávid Horváth under permit · waiting to be applied

Tier 3, bays 1–16 are Unknown. Blocks 2 take-outs for WO-260714-09 and hides 310 pcs of PN-QFN32-MCU7. The rest of SR-02 works.

Troubleshoot SR-02Stays until fixed

Label not recognised

A Würth Elektronik label matched no code rule.

Put-in not finished

Reel R-2026-0109 is waiting for the sensor at SR-01-T4-L31: finish putting it in, or cancel.

Counter ReelSave is failing

Owner: line counter vendorsince 13:48

12 messages waiting. SMT Line 2 counters don't know about reels taken out since 13:48.

Snapshot taken · 14:30

Verified · off-host copy 14:30. Snapshots every 15 min while Janus is busy.

Choose working rack

Scans and bay lights on this station use the working rack. Opening another rack never switches it.

Racks

Help

What the words mean

Language

Applies to this station only. Records keep the words they were written in.

Prototype

Wiring · SR-03

Preview stateSite administrator

View as

This page

Purpose
Boards and channels per tier.
Release
R1
First viewport
1 primary · 1 notice · 3 blocks