:00Thu 24 Sep

COUNT-260714-A · SR-01 tier 5

How a count is posted

The counter pulled each reel, scanned it and pushed it back; the sensor confirmed each reel back in its bay and each empty bay. A bay where the record and the count disagree is a difference.

Each difference is posted once, by a supervisor, with an existing movement. Its receipt lists what it closed.

A closed count is final. A recount is a new count that cites this one.

2 differences to post · 0 of 2 posted

Posting differencesSR-01 · SMT Line 2 · position 1

Differences

L22 · R-2026-0088 recorded, found empty

RecordR-2026-0088 · 2 150 pcsSensorEmpty since 12:52 · bay light red, blinking
Record and sensor

Record

R-2026-0088 · PN-0402-100N
Quantity
2 150 pcs
Put in
Mon 22 Sep 09:14 · Gábor Nagy
Task on it
None · it left without one

Sensor

Empty since 12:52 · no reel at SR-01-T5-L22
Count line
13:05 · found empty
Live
still empty at 14:31
Next bays
L21, L23 match
Sensor at L22 · last 7 days
  1. 14:31
    Still empty
    Live reading
  2. 13:05
    Found empty · count line
    COUNT-260714-A · Gábor Nagy
  3. 12:52
    Reel → empty · no task
    Unexpected removal · bay light blinked red
  4. Mon 09:14
    Empty → reel · R-2026-0088 put in
    Gábor Nagy · sensor confirmed

One change in 7 days. Neighbouring bays match.

L30 · recorded empty, found holding a reel

RecordEmpty · no reel on recordSensorReel since Fri 19 Sep 16:40 · bay light amber, blinking
Record and sensor

Record

Empty · no reel on record at SR-01-T5-L30
Last reel
R-2026-0077 · PN-0603-10K · taken out Fri 19 Sep

Sensor

Reel there since Fri 19 Sep 16:40
Count line
13:05 · found a reel
Live
reel still there at 14:31
Likely
R-2026-0077, put back without a scan
Sensor at L30 · last 7 days
  1. 14:31
    Still a reel
    Live reading
  2. 13:05
    Found a reel · count line
    COUNT-260714-A · Gábor Nagy
  3. Fri 16:40
    Empty → reel · no scan
    Bay light blinked amber
  4. Fri 14:02
    Reel → empty · R-2026-0077 taken out
    Sensor confirmed

Only a supervisor posts these differences.

Bence Tóth (supervisor, Shift B) owns them. A supervisor can scan a badge here to post them.

The count

  1. OpenedWed 24 Sep 12:58 · Katalin Horváth · reels only (done)
  2. Counted13:05 · Gábor Nagy · 20 visited · 11 confirmed empty (done)
  3. Post differences0 of 2
  4. Closed2 still to post · may close with them open

Tier 5 · count lines

SR-01 · SMT Line 2 · position 1
  • Checked · back in its bay
  • Confirmed empty · the sensor
  • Difference · to post

Right now: L22 still empty, L30 still has a reel

All 32 count lines
All 32 count lines
BayRecordCount lineResult
SR-01-T5-L20R-2026-0115 storedScanned · back in its bay 13:02Checked
SR-01-T5-L21EmptyReads Clear · not visitedConfirmed empty
SR-01-T5-L22R-2026-0088 storedReads Clear since 12:52Difference · found empty
SR-01-T5-L23R-2026-0120 storedScanned · back in its bay 13:03Checked
SR-01-T5-L30EmptyReads Present since Fri 16:40Difference · found a reel
17 more checked, 10 more confirmed empty by the sensor.

Alerts

Faults and blocked work stay here until fixed. Notices can be cleared.

SR-02 is limited

Bence Tóth is on itsince 09:41 · 4 h 51 min14:30 installation map v4 drafted by Dávid Horváth under permit · waiting to be applied

Tier 3, bays 1–16 are Unknown. Blocks 2 take-outs for WO-260714-09 and hides 310 pcs of PN-QFN32-MCU7. The rest of SR-02 works.

Handled by the site administrator.Stays until fixed

Label not recognised

A Würth Elektronik label matched no code rule.

Eszter Szabó is told. Put the reel aside.

Put-in not finished

Reel R-2026-0109 is waiting for the sensor at SR-01-T4-L31: finish putting it in, or cancel.

Counter ReelSave is failing

Owner: line counter vendorsince 13:48

12 messages waiting. SMT Line 2 counters don't know about reels taken out since 13:48.

Handled by the site administrator.

Snapshot taken · 14:30

Verified · off-host copy 14:30. Snapshots every 15 min while Janus is busy.

Choose working rack

Scans and bay lights on this station use the working rack. Opening another rack never switches it.

Racks

Help

What the words mean

Language

Applies to this station only. Records keep the words they were written in.

Prototype

COUNT-260714-A · Counts

Preview stateOperator view

View as

This page

Purpose
One Count: its lines, and its differences posted with the movements.
Release
R1
First viewport
1 primary · 1 notice · 3 blocks