:00Thu 24 Sep

COUNT-260714-A · SR-01 tier 5

How a count is posted

The counter pulled each reel, scanned it and pushed it back; the sensor confirmed each reel back in its bay and each empty bay. A bay where the record and the count disagree is a difference.

Each difference is posted once, by a supervisor, with an existing movement. Its receipt lists what it closed.

A closed count is final. A recount is a new count that cites this one.

Closed 14:32 by Bence Tóth

ClosedSR-01 · SMT Line 2 · position 1

Count closed. Every difference posted.

19 checked, 11 confirmed empty by the sensor, 2 of 2 differences posted.

The count record goes into the trace packs of R-2026-0088 and R-2026-0077. Closed is final: a recount is a new count that cites this one.

Recorded · count closed

Count
COUNT-260714-A
Tier
SR-01 tier 5 · 32 bays
Checked
19
Confirmed empty
11 · by the sensor
Differences
2 · 2 posted
Stock
−2 150 pcs PN-0402-100N at SR-01 · R-2026-0088 in Missing · +1 900 pcs PN-0603-10K at SR-01
Closed by
Bence Tóth · 14:32
Two people
Counted by Gábor Nagy · posted by Bence Tóth · closed by Bence Tóth · different people
Entry
Preview · not recorded
  • Closed count differences 1 and 2
  • Closed its task on the counter's device
  • Closed left tower SR-01 · off
Technical details
Thread
CORR-COUNT-790
Request key
cmd_01J8Z7P9QA4C7F0J3M6P9S2V5P9QA

The count

  1. OpenedWed 24 Sep 12:58 · Katalin Horváth · reels only (done)
  2. Counted13:05 · Gábor Nagy · 20 visited · 11 confirmed empty (done)
  3. Post differences2 of 2 (done)
  4. ClosedBence Tóth · 14:32 (done)

Tier 5 · count lines

SR-01 · SMT Line 2 · position 1
  • Checked · back in its bay
  • Confirmed empty · the sensor
  • Difference · to post

Right now: L22 and L30 settled

All 32 count lines
All 32 count lines
BayRecordCount lineResult
SR-01-T5-L20R-2026-0115 storedScanned · back in its bay 13:02Checked
SR-01-T5-L21EmptyReads Clear · not visitedConfirmed empty
SR-01-T5-L22R-2026-0088 storedReads Clear since 12:52Difference · found empty
SR-01-T5-L23R-2026-0120 storedScanned · back in its bay 13:03Checked
SR-01-T5-L30EmptyReads Present since Fri 16:40Difference · found a reel
17 more checked, 10 more confirmed empty by the sensor.

Count record · COUNT-260714-A

Saved as PDF from the print dialog. Cites entry ids, not request keys.

Count record COUNT-260714-A
janus-smt-line2 · generated Wed 24 Sep 2026 14:32 · Janus 0.9.4
What
SR-01 · Reel rack A · tier 5 · 32 bays · SMT Line 2 · position 1 · reels only
Opened
Wed 24 Sep 12:58 · Katalin Horváth (shift supervisor, Shift A)
Counted
13:05 · Gábor Nagy (operator, Shift A) on PDA-03 · 20 bays visited (pull, scan, push back), 11 confirmed empty by the sensor · EV-2456
Posted
14:32 · Bence Tóth and 14:32 · Bence Tóth · not recorded (Preview), not recorded (Preview)
Closed
14:32 · Bence Tóth · not recorded (Preview) · can’t be reopened
Two people
Counted by Gábor Nagy · posted by Bence Tóth · different people
Differences and how they were posted
BayRecordCount line 13:05Posted · reasonEntry
SR-01-T5-L22R-2026-0088 · 2 150 pcsFound empty · Clear since 12:52R-2026-0088 → Missing (by decision) · L22 empty on record · “Searched tier 5. Checked the returns cart.”not recorded (Preview)
SR-01-T5-L30EmptyFound a reel · Present since Fri 19 Sep 16:40R-2026-0077 recorded at L30 · 1 900 pcs · “Put back by hand after a take-out.”not recorded (Preview)
The other 30 lines settled: 19 checked (a scan, then the reel back in its bay), 11 confirmed empty by the sensor.
Stock effect
−2 150 pcs PN-0402-100N at SR-01 · R-2026-0088 in Missing · +1 900 pcs PN-0603-10K at SR-01
Thread
CORR-COUNT-790
In trace packs
R-2026-0088 · R-2026-0077 · LOT-2602-008

Alerts

Faults and blocked work stay here until fixed. Notices can be cleared.

SR-02 is limited

Bence Tóth is on itsince 09:41 · 4 h 51 min14:30 installation map v4 drafted by Dávid Horváth under permit · waiting to be applied

Tier 3, bays 1–16 are Unknown. Blocks 2 take-outs for WO-260714-09 and hides 310 pcs of PN-QFN32-MCU7. The rest of SR-02 works.

Troubleshoot SR-02Stays until fixed

Label not recognised

A Würth Elektronik label matched no code rule.

Eszter Szabó is told. Put the reel aside.

Put-in not finished

Reel R-2026-0109 is waiting for the sensor at SR-01-T4-L31: finish putting it in, or cancel.

Counter ReelSave is failing

Owner: line counter vendorsince 13:48

12 messages waiting. SMT Line 2 counters don't know about reels taken out since 13:48.

Handled by the site administrator.

Snapshot taken · 14:30

Verified · off-host copy 14:30. Snapshots every 15 min while Janus is busy.

Choose working rack

Scans and bay lights on this station use the working rack. Opening another rack never switches it.

Racks

Help

What the words mean

Language

Applies to this station only. Records keep the words they were written in.

Prototype

COUNT-260714-A · Counts

Preview stateClosed

View as

This page

Purpose
One Count: its lines, and its differences posted with the movements.
Release
R1
First viewport
1 primary · 1 notice · 3 blocks